Pullout Capacity of Horizontally Loaded Suction Anchor Installed in Silty Sand
Current floating structures require more reliable and higher anchoring capacities because of their increased size. A suction anchor is one of the most popular anchors for a floating system. In this study, the behavior of a suction anchor installed in cohesionless soil was investigated when the anchor was subjected to mainly a horizontal load. Three-dimensional finite element numerical analyses were carried out using ABAQUS, and three centrifuge tests were performed to calibrate the numerical analyses. A parametric study with different dimensions and loading points for the suction anchor was conducted. The horizontal capacity of the suction anchor was estimated, and the soil reaction distribution was analyzed when the load was applied at the optimal point. Based on the results, an analytical equation for calculating the horizontal capacity of a suction anchor was proposed that can be easily adopted for design.
Pullout Capacity of Horizontally Loaded Suction Anchor Installed in Silty Sand
Current floating structures require more reliable and higher anchoring capacities because of their increased size. A suction anchor is one of the most popular anchors for a floating system. In this study, the behavior of a suction anchor installed in cohesionless soil was investigated when the anchor was subjected to mainly a horizontal load. Three-dimensional finite element numerical analyses were carried out using ABAQUS, and three centrifuge tests were performed to calibrate the numerical analyses. A parametric study with different dimensions and loading points for the suction anchor was conducted. The horizontal capacity of the suction anchor was estimated, and the soil reaction distribution was analyzed when the load was applied at the optimal point. Based on the results, an analytical equation for calculating the horizontal capacity of a suction anchor was proposed that can be easily adopted for design.
Pullout Capacity of Horizontally Loaded Suction Anchor Installed in Silty Sand
Kim, Surin (author) / Choo, Yun Wook (author) / Kim, Dong-Soo (author)
Marine Georesources & Geotechnology ; 34 ; 87-95
2016-01-02
9 pages
Article (Journal)
Electronic Resource
English
Pullout Capacity of Horizontally Loaded Suction Anchor Installed in Silty Sand
Online Contents | 2016
|Pullout Capacity of Horizontally Loaded Suction Anchor Installed in Silty Sand
Online Contents | 2014
|Investigation of suction anchor pullout capacity under undrained conditions
BASE | 2015
|Pullout Capacity of Block Anchor in Unsaturated Sand
ASCE | 2006
|