A platform for research: civil engineering, architecture and urbanism
Antimony film sensor for sensitive rare earth metal analysis in environmental samples
A sensor for the adsorptive stripping voltammetric determination of rare earth elements has been developed. The electrochemical procedure is based on the oxidation of the rare earth elements complexed with alizarin complexone at a glassy carbon electrode that was in situ modified with an antimony film, during an anodic scan from –0.2 V to 1.1 V (vs. Ag/AgCl) and deposition potential of –0.1 V (vs. Ag/AgCl). The factors influencing the adsorptive stripping capability were optimised, including the complexing agent concentration, plating concentration of antimony and deposition time. The detection of rare earth elements (La, Ce and Pr) were realised in 0.08 M sodium acetate (pH = 5.8) solution as supporting electrolyte, with 2 × 10−6 M alizarin complexone and 1.0 mg L−1 antimony solution. Under the optimised conditions, a deposition time of 360 s was obtained and a linear response was observed between 1 and 25 µg L−1. The reproducibility of the voltammetric measurements was found to be within 5.0% RSD for 12 replicate measurements of cerium(III) concentration of 5 µg L−1 using the same electrode surface. The detection limits obtained using stripping analysis was 0.06, 0.42 and 0.71 μg L−1 for Ce(III), La(III) and Pr(III), respectively. The developed sensor has been successfully applied for the determination of cerium, lanthanum and praseodymium in municipal tap water samples.
Antimony film sensor for sensitive rare earth metal analysis in environmental samples
A sensor for the adsorptive stripping voltammetric determination of rare earth elements has been developed. The electrochemical procedure is based on the oxidation of the rare earth elements complexed with alizarin complexone at a glassy carbon electrode that was in situ modified with an antimony film, during an anodic scan from –0.2 V to 1.1 V (vs. Ag/AgCl) and deposition potential of –0.1 V (vs. Ag/AgCl). The factors influencing the adsorptive stripping capability were optimised, including the complexing agent concentration, plating concentration of antimony and deposition time. The detection of rare earth elements (La, Ce and Pr) were realised in 0.08 M sodium acetate (pH = 5.8) solution as supporting electrolyte, with 2 × 10−6 M alizarin complexone and 1.0 mg L−1 antimony solution. Under the optimised conditions, a deposition time of 360 s was obtained and a linear response was observed between 1 and 25 µg L−1. The reproducibility of the voltammetric measurements was found to be within 5.0% RSD for 12 replicate measurements of cerium(III) concentration of 5 µg L−1 using the same electrode surface. The detection limits obtained using stripping analysis was 0.06, 0.42 and 0.71 μg L−1 for Ce(III), La(III) and Pr(III), respectively. The developed sensor has been successfully applied for the determination of cerium, lanthanum and praseodymium in municipal tap water samples.
Antimony film sensor for sensitive rare earth metal analysis in environmental samples
Makombe, Martin (author) / van der Horst, Charlton (author) / Silwana, Bongiwe (author) / Iwuoha, Emmanuel (author) / Somerset, Vernon (author)
Journal of Environmental Science and Health, Part A ; 51 ; 597-606
2016-07-02
10 pages
Article (Journal)
Electronic Resource
English
Antimony film sensor for sensitive rare earth metal analysis in environmental samples
Online Contents | 2016
|European Patent Office | 2023
|Rare Earth Metal Doped Barium Titanates
British Library Online Contents | 2008
|LC-ICP-OES method for antimony speciation analysis in liquid samples
Taylor & Francis Verlag | 2020
|Statistical analysis of groundwater and slate samples with special influences on rare earth elements
BASE | 2012
|