A platform for research: civil engineering, architecture and urbanism
Application of the U.S. EPA procedure for determining method detection limits to EDXRF measurement of filter-based aerosol samples
The U.S. Environmental Protection Agency (EPA) modified its guidance on determining “method detection limits” (MDL) in 2017. The recommended procedures have not yet been applied to the analyses routinely done on filter samples for EPA’s Chemical Speciation Network (CSN). This paper applies the new EPA procedure for estimating MDL to Energy Dispersive X-Ray Fluorescence (EDXRF) analysis of atmospheric aerosol samples collected on filters. The procedure involves estimating MDL by two approaches – statistical distributions of unloaded blank sample measurements and lightly loaded, spiked samples – and sets the MDL as the maximum of these two approaches. Spiked samples at low concentrations were developed using an aerosol deposition chamber to follow this approach. The MDL procedure was initially conducted on one EDXRF instrument, and the spike-based MDL was found to be higher than blank-based MDL for 28 of the 31 elements. The blank-based MDL was higher than the spike-based MDL for Si, K and Fe, which are common contaminants present in filter raw media or arising from EDXRF hardware. The annual verification performed using five EDXRF analyzers demonstrated that the MDL estimated following the EPA procedure was stable over time and analyzers for all elements except K, which yielded a higher MDL.
Implications: Lightly loaded reference materials (RM) were developed for Energy Dispersive X-ray Fluorescence (EDXRF) measurements of elemental concentrations in filter-based particulate matter samples using a novel aerosol generation chamber. These RM were then used to estimate method detection limits (MDL) following U.S. Environmental Protection Agency guidance. These new MDL estimates were compared to alternative estimates and, for most elements, are higher. Our work provides EDXRF users with MDL estimates for each element and an assessment of different MDL estimation approaches.
Application of the U.S. EPA procedure for determining method detection limits to EDXRF measurement of filter-based aerosol samples
The U.S. Environmental Protection Agency (EPA) modified its guidance on determining “method detection limits” (MDL) in 2017. The recommended procedures have not yet been applied to the analyses routinely done on filter samples for EPA’s Chemical Speciation Network (CSN). This paper applies the new EPA procedure for estimating MDL to Energy Dispersive X-Ray Fluorescence (EDXRF) analysis of atmospheric aerosol samples collected on filters. The procedure involves estimating MDL by two approaches – statistical distributions of unloaded blank sample measurements and lightly loaded, spiked samples – and sets the MDL as the maximum of these two approaches. Spiked samples at low concentrations were developed using an aerosol deposition chamber to follow this approach. The MDL procedure was initially conducted on one EDXRF instrument, and the spike-based MDL was found to be higher than blank-based MDL for 28 of the 31 elements. The blank-based MDL was higher than the spike-based MDL for Si, K and Fe, which are common contaminants present in filter raw media or arising from EDXRF hardware. The annual verification performed using five EDXRF analyzers demonstrated that the MDL estimated following the EPA procedure was stable over time and analyzers for all elements except K, which yielded a higher MDL.
Implications: Lightly loaded reference materials (RM) were developed for Energy Dispersive X-ray Fluorescence (EDXRF) measurements of elemental concentrations in filter-based particulate matter samples using a novel aerosol generation chamber. These RM were then used to estimate method detection limits (MDL) following U.S. Environmental Protection Agency guidance. These new MDL estimates were compared to alternative estimates and, for most elements, are higher. Our work provides EDXRF users with MDL estimates for each element and an assessment of different MDL estimation approaches.
Application of the U.S. EPA procedure for determining method detection limits to EDXRF measurement of filter-based aerosol samples
Hyslop, Nicole Pauly (author) / Liu, Yifan (author) / Yatkin, Sinan (author) / Trzepla, Krystyna (author)
Journal of the Air & Waste Management Association ; 72 ; 905-913
2022-08-03
9 pages
Article (Journal)
Electronic Resource
Unknown
Preparation of Natural Material Samples for EDXRF Analysis
British Library Online Contents | 1994
|British Library Online Contents | 2005
On-line Measurement of Cement Raw Meal Utilizing EDXRF
British Library Conference Proceedings | 2000
|A New Procedure for Determining Detection and Quantitation Limits in Wastewater Analysis
British Library Conference Proceedings | 2008
|EDXRF study of Tupiguarani archaeological ceramics
British Library Conference Proceedings | 1999
|