A platform for research: civil engineering, architecture and urbanism
Impact of weather variation on ground-source heat pump design
This article presents an investigation on the impact of year-to-year weather variability on the optimal design of a system for heating and cooling a building using a ground-source heat pump. The designs of a boiler–ground-source heat pump hybrid and a cooling tower–ground-source heat pump hybrid were optimized using a typical meteorological year (TMY2) weather file and also using 15 years of actual weather data. The results indicate that a design based on a TMY2 weather file may be undersized for a severe weather year; this is particularly true if the severe weather year is encountered during the first year of system operation. A cooling tower–ground-source heat pump hybrid model was developed, which includes the use of a backup boiler placed on the building side (rather than the loop side) of the system. It was found that the use of a boiler backup mitigated much of the negative impact of a severe weather year. The boiler supplied the heating during periods of particularly severe weather so that the ground loop length could be maintained at a reasonable value.
Impact of weather variation on ground-source heat pump design
This article presents an investigation on the impact of year-to-year weather variability on the optimal design of a system for heating and cooling a building using a ground-source heat pump. The designs of a boiler–ground-source heat pump hybrid and a cooling tower–ground-source heat pump hybrid were optimized using a typical meteorological year (TMY2) weather file and also using 15 years of actual weather data. The results indicate that a design based on a TMY2 weather file may be undersized for a severe weather year; this is particularly true if the severe weather year is encountered during the first year of system operation. A cooling tower–ground-source heat pump hybrid model was developed, which includes the use of a backup boiler placed on the building side (rather than the loop side) of the system. It was found that the use of a boiler backup mitigated much of the negative impact of a severe weather year. The boiler supplied the heating during periods of particularly severe weather so that the ground loop length could be maintained at a reasonable value.
Impact of weather variation on ground-source heat pump design
Pertzborn, Amanda (author) / Nellis, Greg (author) / Klein, Sanford (author)
HVAC&R Research ; 17 ; 174-185
2011-04-08
12 pages
Article (Journal)
Electronic Resource
Unknown
Field Tests for Ground Thermal Properties-Methods and Impact on Ground-Source Heat Pump Design
British Library Conference Proceedings | 2000
|Field Tests for Ground Thermal Properties-Methods and Impact on Ground-Source Heat Pump Design
British Library Online Contents | 2000
|The Effects of Weather Conditions on Domestic Ground-Source Heat Pump Performance in the UK
Springer Verlag | 2013
|