A platform for research: civil engineering, architecture and urbanism
Water-Based Condensation Particle Counters for Environmental Monitoring of Ultrafine Particles
TSI Inc. (Shoreview, MN) has introduced three new water-based condensation particle counters (WCPCS) that were designed to detect airborne particles larger than 2.5 nm (model 3786), 5 nm (model 3785), and either 10 or 20 nm (model 3782). These WCPCs are well suited for real time, environmental monitoring of number concentration of airborne ultrafine particles. Their unique design incorporates the use of water as the working fluid instead of alcohol. Water is odor free, readily available, and eliminates the problem of water condensation and absorption into alcohol working fluids during operation in humid environments. In this study, the performance of three TSI WCPCs was characterized for several aerosol compositions, including sucrose, salt (NaCl), dioctyl sebacate (DOS), dioctyl phthalate (DOP), emery oil (poly-alpha-olefin), silver, impurity residue particles, and ambient aerosol particles. All particles were size selected using a nano differential mobility analyzer (nano-DMA; model 3085, TSI Inc.) to create monodisperse challenge aerosols. The challenge aerosol was mixed uniformly with clean makeup flow and split into a WCPC and a reference instrument to determine the counting efficiency of the WCPC. For the model 3785 WCPC, the D50 (i.e., the particle diameter with 50% counting efficiency) was determined to be 3.1 nm for salt particles, 4.7 nm for sucrose and ambient particles, 5.6 nm for silver particles, and >50 nm for ultrapure oil particles. The sensitivity to oil droplets increased dramatically (D50 < 10 nm) when the oil was slightly contaminated. The D50 of model 3786 ultra-fine water-based CPC (UWCPC) was 2.4 nm for impurity residue particles. The D50 of the model 3782 WCPC was 10.8 (with a nominal setting of 10 nm) or 19.8 nm (with a nominal setting of 20 nm) for sucrose particles. All three WCPCs have response times of less than 2 or 3 sec and are therefore able to detect fast-changing events.
Water-Based Condensation Particle Counters for Environmental Monitoring of Ultrafine Particles
TSI Inc. (Shoreview, MN) has introduced three new water-based condensation particle counters (WCPCS) that were designed to detect airborne particles larger than 2.5 nm (model 3786), 5 nm (model 3785), and either 10 or 20 nm (model 3782). These WCPCs are well suited for real time, environmental monitoring of number concentration of airborne ultrafine particles. Their unique design incorporates the use of water as the working fluid instead of alcohol. Water is odor free, readily available, and eliminates the problem of water condensation and absorption into alcohol working fluids during operation in humid environments. In this study, the performance of three TSI WCPCs was characterized for several aerosol compositions, including sucrose, salt (NaCl), dioctyl sebacate (DOS), dioctyl phthalate (DOP), emery oil (poly-alpha-olefin), silver, impurity residue particles, and ambient aerosol particles. All particles were size selected using a nano differential mobility analyzer (nano-DMA; model 3085, TSI Inc.) to create monodisperse challenge aerosols. The challenge aerosol was mixed uniformly with clean makeup flow and split into a WCPC and a reference instrument to determine the counting efficiency of the WCPC. For the model 3785 WCPC, the D50 (i.e., the particle diameter with 50% counting efficiency) was determined to be 3.1 nm for salt particles, 4.7 nm for sucrose and ambient particles, 5.6 nm for silver particles, and >50 nm for ultrapure oil particles. The sensitivity to oil droplets increased dramatically (D50 < 10 nm) when the oil was slightly contaminated. The D50 of model 3786 ultra-fine water-based CPC (UWCPC) was 2.4 nm for impurity residue particles. The D50 of the model 3782 WCPC was 10.8 (with a nominal setting of 10 nm) or 19.8 nm (with a nominal setting of 20 nm) for sucrose particles. All three WCPCs have response times of less than 2 or 3 sec and are therefore able to detect fast-changing events.
Water-Based Condensation Particle Counters for Environmental Monitoring of Ultrafine Particles
Liu, Wei (author) / Kaufman, Stanley L. (author) / Osmondson, Brian L. (author) / Sem, Gilmore J. (author) / Quant, Frederick R. (author) / Oberreit, Derek R. (author)
Journal of the Air & Waste Management Association ; 56 ; 444-455
2006-04-01
12 pages
Article (Journal)
Electronic Resource
Unknown
Water-Based Condensation Particle Counters for Environmental Monitoring of Ultrafine Particles
British Library Conference Proceedings | 2006
|Note on the smallest particles detected by condensation nucleus counters
Elsevier | 1974
|Measuring particles in drinking water transportation systems with particle counters
Online Contents | 2007
|Measuring particles in drinking water transportation systems with particle counters
British Library Online Contents | 2007
|Selecting Particle Counters for Process Monitoring
Wiley | 1992
|