A platform for research: civil engineering, architecture and urbanism
Bridging the domestic building fabric performance gap
It is recognized that there is often a discrepancy between the measured fabric thermal performance of dwellings as built and the predicted performance of the same dwellings and that the magnitude of this difference in performance can be quite large. This paper presents the results of a number of in-depth building fabric thermal performance tests undertaken on three case study dwellings located on two separate Passivhaus developments in the UK: one masonry cavity and the other two timber-frame. The results from the tests revealed that all the case study dwellings performed very close to that predicted. This is in contrast with other work that has been undertaken regarding the performance of the building fabric, which indicates that a very wide range of performance exists in new-build dwellings in the UK, and that the difference between the measured and predicted fabric performance can be greater than 100%. Despite the small non-random size of the sample, the results suggest that careful design coupled with the implementation of appropriate quality control systems, such as those required to attain Passivhaus Certification, may be conducive to delivering dwellings that begin to ‘bridge the gap’ between measured and predicted fabric performance.
Bridging the domestic building fabric performance gap
It is recognized that there is often a discrepancy between the measured fabric thermal performance of dwellings as built and the predicted performance of the same dwellings and that the magnitude of this difference in performance can be quite large. This paper presents the results of a number of in-depth building fabric thermal performance tests undertaken on three case study dwellings located on two separate Passivhaus developments in the UK: one masonry cavity and the other two timber-frame. The results from the tests revealed that all the case study dwellings performed very close to that predicted. This is in contrast with other work that has been undertaken regarding the performance of the building fabric, which indicates that a very wide range of performance exists in new-build dwellings in the UK, and that the difference between the measured and predicted fabric performance can be greater than 100%. Despite the small non-random size of the sample, the results suggest that careful design coupled with the implementation of appropriate quality control systems, such as those required to attain Passivhaus Certification, may be conducive to delivering dwellings that begin to ‘bridge the gap’ between measured and predicted fabric performance.
Bridging the domestic building fabric performance gap
Johnston, D. (author) / Farmer, D. (author) / Brooke-Peat, M. (author) / Miles-Shenton, D. (author)
Building Research & Information ; 44 ; 147-159
2016-02-17
13 pages
Article (Journal)
Electronic Resource
English
Bridging the domestic building fabric performance gap
Online Contents | 2016
|Bridging the domestic building fabric performance gap
British Library Online Contents | 2016
|Quantifying the domestic building fabric ‘performance gap’