A platform for research: civil engineering, architecture and urbanism
Decoupling of undamped vibration systems
Decoupling of a multimass vibration system from a large structure is investigated. First the dynamic influence on the foundation (or floor) response spectra of the inertia of the subcomponent system is studied using time-history input. Secondly, the affect of coupling on the natural frequencies of both the structure and subcomponent system are studied using formulas developed from normal mode theory. Results of these studies show that equipment-structure interaction cannot be neglected if the subcomponent is in resonance with the structure. The foundataion (or floor) response spectra is significantly reduced at original peaks in these curves. Shifts in frequency of the system are also more pronounced at this resonant condition. Estimates of frequency changes of both the structure and subcomponent are related to a ratio of the modal masses of the subcomponent and the mass of the structure.
Decoupling of undamped vibration systems
Decoupling of a multimass vibration system from a large structure is investigated. First the dynamic influence on the foundation (or floor) response spectra of the inertia of the subcomponent system is studied using time-history input. Secondly, the affect of coupling on the natural frequencies of both the structure and subcomponent system are studied using formulas developed from normal mode theory. Results of these studies show that equipment-structure interaction cannot be neglected if the subcomponent is in resonance with the structure. The foundataion (or floor) response spectra is significantly reduced at original peaks in these curves. Shifts in frequency of the system are also more pronounced at this resonant condition. Estimates of frequency changes of both the structure and subcomponent are related to a ratio of the modal masses of the subcomponent and the mass of the structure.
Decoupling of undamped vibration systems
Entkoppelung eines ungedaempften Schwingungssystems
Scavuzzo, R. (author) / Lam, P. (author)
ASME-Papers ; 1-10
1977
10 Seiten, 13 Bilder, 8 Tabellen, 3 Quellen
Conference paper
English
Predicting distribution of aeolian vibration amplitude of undamped overhead transmission lines
Elsevier | 2024
|Undamped Vibration of Laminated Fiber-Reinforced Polymer Pipes in Water Hammer Conditions
Online Contents | 2015
|Undamped non-linear vibration mechanism of bolted flange joint under transverse load
DOAJ | 2023
|Undamped non-linear vibration mechanism of bolted flange joint under transverse load
Taylor & Francis Verlag | 2023
|Analysis of Damped and Undamped Systems Using DFT
British Library Conference Proceedings | 1996
|