A platform for research: civil engineering, architecture and urbanism
Review clogging behavior by the modified Gradient Ratio test device with implanted piezometers
A modified implanted Gradient Ratio (GR) test system was proposed in the study. In comparison with the conventional GR test device, all the piezometers are implanted into the soil specimen, and an additional piezometer is installed at soil-geotextile interface, in order to precisely measure the pore pressure variation of the soil-geotextile system. By using the modified GR test apparatus, 120 tests were conducted to study the clogging behavior of soil-geotextile system. Four types of needle-punched nonwoven geotextiles and five gap-graded soil mixtures were used in the program. These soils are the mixture of the Ottawa sand and various percentages of weathered mudstone. Three hydraulic gradients were used in the GR tests. The results of the study indicated that the modified implanted GR test system is able to provide pore pressure head measurement within the test specimen. In general, GR values obtained from the implanted GR test system are greater than those obtained from the conventional GR tests.
Review clogging behavior by the modified Gradient Ratio test device with implanted piezometers
A modified implanted Gradient Ratio (GR) test system was proposed in the study. In comparison with the conventional GR test device, all the piezometers are implanted into the soil specimen, and an additional piezometer is installed at soil-geotextile interface, in order to precisely measure the pore pressure variation of the soil-geotextile system. By using the modified GR test apparatus, 120 tests were conducted to study the clogging behavior of soil-geotextile system. Four types of needle-punched nonwoven geotextiles and five gap-graded soil mixtures were used in the program. These soils are the mixture of the Ottawa sand and various percentages of weathered mudstone. Three hydraulic gradients were used in the GR tests. The results of the study indicated that the modified implanted GR test system is able to provide pore pressure head measurement within the test specimen. In general, GR values obtained from the implanted GR test system are greater than those obtained from the conventional GR tests.
Review clogging behavior by the modified Gradient Ratio test device with implanted piezometers
Chang, D.T. (author) / Hsieh, Chiwan (author) / Chen, Shih-Yueh (author) / Chen, You-Quan (author)
2000
13 Seiten, 11 Quellen
Conference paper
English
Review Clogging Behavior by the Modified Gradient Ratio Test Device with Implanted Piezometers
British Library Conference Proceedings | 2000
|British Library Conference Proceedings | 1999
|Earth pressures measured with hydraulic piezometers
TIBKAT | 1975
|Significance of Gradient Ratio Test for Determining Clogging Potential of Geotextiles
British Library Conference Proceedings | 1996
|Piezometers for Groundwater Measurement and Monitoring
Wiley | 2007
|