A platform for research: civil engineering, architecture and urbanism
Toxic product yields and hazard assessment for fully enclosed design fires
Fires in multi-compartment buildings often occur in enclosed spaces or in enclosures opening into other rooms or corridors. Where such fires occur in relatively small enclosures, with limited external venting, the growth of the fire remains restricted. If large vents are present opening into large enclosed spaces or to the outside, flashover may occur. In either case, these fires are likely to become oxygen-vitiated, producing large amounts of smoke and toxic products. FR (fire-retarded ) and non-FR materials behave differently in these situations from the well-ventilated conditions in most standard test, with smaller differences in toxic product yields. The main hazard to building occupants is the rapid contamination of building spaces by toxic smoke. Visual obscuration and irritancy of smoke impedes escape efficiency, affecting escape behavior and slowing travel speeds. This may be followed by incapacitation, primarily due to exposure to asphyxiant gases (mainly CO and HCN), and death. A series of full-scale fire tests conducted in enclosed test rigs and buildings is reported, in which detailed measuremenst of smoke, heat, toxic gases and time to detection were made, enabling assessment of time to incapacitation using the Fractional Effective Dose methodology. Also described are hazard analyses for fires in which an active suppression was used. These include fires in two-storey maisonettes with and without domestic sprinklers. Results are presented on the relationship between plume oxygen and CO concentrations, and between CO and HCN yields. The effects of interaction between fuel type and load, ventilation and building enclosures are discussed and their implications for choice of design fires appropriate to different scenarios.
Toxic product yields and hazard assessment for fully enclosed design fires
Fires in multi-compartment buildings often occur in enclosed spaces or in enclosures opening into other rooms or corridors. Where such fires occur in relatively small enclosures, with limited external venting, the growth of the fire remains restricted. If large vents are present opening into large enclosed spaces or to the outside, flashover may occur. In either case, these fires are likely to become oxygen-vitiated, producing large amounts of smoke and toxic products. FR (fire-retarded ) and non-FR materials behave differently in these situations from the well-ventilated conditions in most standard test, with smaller differences in toxic product yields. The main hazard to building occupants is the rapid contamination of building spaces by toxic smoke. Visual obscuration and irritancy of smoke impedes escape efficiency, affecting escape behavior and slowing travel speeds. This may be followed by incapacitation, primarily due to exposure to asphyxiant gases (mainly CO and HCN), and death. A series of full-scale fire tests conducted in enclosed test rigs and buildings is reported, in which detailed measuremenst of smoke, heat, toxic gases and time to detection were made, enabling assessment of time to incapacitation using the Fractional Effective Dose methodology. Also described are hazard analyses for fires in which an active suppression was used. These include fires in two-storey maisonettes with and without domestic sprinklers. Results are presented on the relationship between plume oxygen and CO concentrations, and between CO and HCN yields. The effects of interaction between fuel type and load, ventilation and building enclosures are discussed and their implications for choice of design fires appropriate to different scenarios.
Toxic product yields and hazard assessment for fully enclosed design fires
Purser, D.A. (author)
Polymer International ; 49 ; 1232-1255
2000
24 Seiten, 16 Bilder, 9 Tabellen, 21 Quellen
Article (Journal)
English
mehrstöckiges Gebäude , Belüftung , Rauchentwicklung , Giftgas , Schadstoffexposition , Kohlenmonoxid , Toxizität , Blausäure , Flammverzögerer , Risikoanalyse , Risiko (Gesundheit) , Luftverunreinigung , Möbelbezugsstoff , Selbstlöschung , Feuersicherheit , menschliches Verhalten , Sicherheitssystem
British Library Conference Proceedings | 1999
|The Gravimetric Determination of Soot Yields in Enclosed Pool Fires
British Library Conference Proceedings | 2001
|FTIR Investigations of Toxic Gases in Air Starved Enclosed Fires
British Library Conference Proceedings | 2005
|Correlation of Toxic Product Yields from Tube Furnace Tests and Large Scale Fires
British Library Conference Proceedings | 2005
|Physical Modelling of Enclosed Pool Fires
NTIS | 1987
|