A platform for research: civil engineering, architecture and urbanism
Assessment on heat release rate of furniture foam arrangement by a cone calorimeter
Heat release rate of a typical furniture foam sofa was assessed with a cone calorimeter. The sofa arrangement included two layers of fabric, cotton and foam. Individual component materials and combination of them were tested. A high radiative heat flux of 50 kWm-2 was used to consume all materials in the tests. The sustained ignition time, peak heat release rate and total heat release rate were deduced from the heat release rate curves. These data are useful for classifying the materials by calculating two parameters describing the possibility to flashover. The superposition of heat release rate curves and total heat released (THR) were studied. It is observed that adding the heat release rate curves for component materials would not give the heat release rate curve of a furniture arrangement with different combinations of materials. However, the THR for the components can be added to give the THR of the arrangement.
Assessment on heat release rate of furniture foam arrangement by a cone calorimeter
Heat release rate of a typical furniture foam sofa was assessed with a cone calorimeter. The sofa arrangement included two layers of fabric, cotton and foam. Individual component materials and combination of them were tested. A high radiative heat flux of 50 kWm-2 was used to consume all materials in the tests. The sustained ignition time, peak heat release rate and total heat release rate were deduced from the heat release rate curves. These data are useful for classifying the materials by calculating two parameters describing the possibility to flashover. The superposition of heat release rate curves and total heat released (THR) were studied. It is observed that adding the heat release rate curves for component materials would not give the heat release rate curve of a furniture arrangement with different combinations of materials. However, the THR for the components can be added to give the THR of the arrangement.
Assessment on heat release rate of furniture foam arrangement by a cone calorimeter
Bestimmung der Wärmefreisetzungsgeschwindigkeit von einem Verbund von Möbelschaum in einem Kegelkalorimeter
Chow, W.K. (author)
Journal of Fire Sciences ; 20 ; 319-328
2002
10 Seiten, 4 Bilder, 1 Tabelle, 11 Quellen
Article (Journal)
English
Assessment on Heat Release Rate of Furniture Foam Arrangement by a Cone Calorimeter
British Library Online Contents | 2002
|Assessment on Heat Release Rate of Furniture Foam Arrangement by a Cone Calorimeter
Online Contents | 2002
|Rate of heat release measurement using the Cone Calorimeter
Springer Verlag | 1989
|Cone Calorimeter Studies of Furniture Component System
British Library Conference Proceedings | 1994
|Influence of Ignition Sources on Heat Release Rate in the Furniture Calorimeter
British Library Online Contents | 1996
|