A platform for research: civil engineering, architecture and urbanism
Fire hazard assessment on polyurethane sandwich panels for temporary accommodation units
Fire hazard assessment on sandwich panels used for constructing temporary accommodation units (TAUs) is discussed. The requirements imposed by the three responsible local government departments, i.e. Buildings Department, Fire Services Department and Labour Department, are outlined. A typical sandwich panel used for constructing TAUs was assessed by a cone calorimeter. Four radiative heat fluxes of 20, 25, 50 and 65 kW m-2 were applied to study the sustained ignition time, peak heat release rate, average heat release rates in 60 and 180 s after ignition, total heat release rate, mass loss percentage, total smoke release, carbon monoxide and carbon dioxide yields. From these data, the possibilities of flashover and smoke aspects were studied. Preliminary recommendations on what should be considered in specifying fire tests for new regulations on the use of these sandwich panels are made.
Fire hazard assessment on polyurethane sandwich panels for temporary accommodation units
Fire hazard assessment on sandwich panels used for constructing temporary accommodation units (TAUs) is discussed. The requirements imposed by the three responsible local government departments, i.e. Buildings Department, Fire Services Department and Labour Department, are outlined. A typical sandwich panel used for constructing TAUs was assessed by a cone calorimeter. Four radiative heat fluxes of 20, 25, 50 and 65 kW m-2 were applied to study the sustained ignition time, peak heat release rate, average heat release rates in 60 and 180 s after ignition, total heat release rate, mass loss percentage, total smoke release, carbon monoxide and carbon dioxide yields. From these data, the possibilities of flashover and smoke aspects were studied. Preliminary recommendations on what should be considered in specifying fire tests for new regulations on the use of these sandwich panels are made.
Fire hazard assessment on polyurethane sandwich panels for temporary accommodation units
Chow, W.K. (author)
Polymer Testing ; 23 ; 973-977
2004
5 Seiten
Article (Journal)
English
Fire hazard assessment on polyurethane sandwich panels for temporary accommodation units
British Library Online Contents | 2004
|Sandwich Panel Debate Fire Hazard of Sandwich Panels: The Effect of Fire Load
British Library Online Contents | 2001
|Sandwich Panel Debate Fire Hazard of Sandwich Panels: The Effect of Thermal Insulation
British Library Online Contents | 2001
|Lighting Diffuser Panels - Fire Hazard
British Library Online Contents | 1996
|