A platform for research: civil engineering, architecture and urbanism
Pure torsion tests on single hollow core slabs
Four tests on prestressed hollow core slab units were carried out. The slab units, two of them 200 mm and two 400 mm in thickness, were subjected to pure torsion. In all tests the observed failure mode was the same as the predicted one, i.e. cracking of top flange in angle of 45 deg of angle with the longitudinal axis of the slab unit. Although the failure mode was abrupt, the slab units showed considerable ductility after the failure. None of them collapsed before the test had to be interrupted due to excessive rotation. For 400 mm slabs the torsional stiffness observed in the tests was close to that predicted by elementary calculation method, but for 200 mm slabs the predicted stiffness was 30 % lower than that observed. The predicted torsional resistance was 60 % and 70 % of the observed resistance for 200 mm and 400 mm slabs, respectively, when the lower characteristic value for the tensile strength of the concrete was used for prediction.
Pure torsion tests on single hollow core slabs
Four tests on prestressed hollow core slab units were carried out. The slab units, two of them 200 mm and two 400 mm in thickness, were subjected to pure torsion. In all tests the observed failure mode was the same as the predicted one, i.e. cracking of top flange in angle of 45 deg of angle with the longitudinal axis of the slab unit. Although the failure mode was abrupt, the slab units showed considerable ductility after the failure. None of them collapsed before the test had to be interrupted due to excessive rotation. For 400 mm slabs the torsional stiffness observed in the tests was close to that predicted by elementary calculation method, but for 200 mm slabs the predicted stiffness was 30 % lower than that observed. The predicted torsional resistance was 60 % and 70 % of the observed resistance for 200 mm and 400 mm slabs, respectively, when the lower characteristic value for the tensile strength of the concrete was used for prediction.
Pure torsion tests on single hollow core slabs
Reine Torsionsprüfungen an einzelnen Hohlkernplatten
Pajari, Matti (author)
2004
64 Seiten, Bilder
Miscellaneous
English
Shear-torsion interaction tests on single hollow core slabs
Tema Archive | 2004
|Shear and Torsion in Hollow Core Slabs
British Library Conference Proceedings | 2005
|Shear-torsion tests on 400 mm hollow core floor
Tema Archive | 2004
|Shear-torsion tests on 200 mm hollow core floor
Tema Archive | 2004
|