A platform for research: civil engineering, architecture and urbanism
Surface crack detection by flash thermography on concrete surface
Cracking may impair the durability of concrete by allowing immigration of external aggressive agents; therefore, crack monitoring is always a vital part in building pathology. This study proposes to apply short-duration pulsed thermography - flash thermography (FT) - for surface crack detection. This method allows full-field and non-contact qualitative observation of thermal radiation from an object surface and is highly accepted in the aerospace industry. It is superior to the common practice of surface crack detection - visual inspection. The overall inspection time is reduced and hence maintenance costs lowered. During inspection, the inspected surface is excited with a heat-pulse of short duration (~3 ms). Surface cracking is detected based on the difference in heat emission between cracks and intact region. The results show that FT can detect surface cracks with 0.5 mm to 1 mm crack width successfully but micro-cracks (0.1 mm-0.5 mm) can only be detected by adding water with FT. In addition, this study also compared the performances of traditional Sobel and Canny edge detectors and a proposed shear image subtraction method, for crack detection. The results show that the sheared image subtraction method is significantly more effective than the other two edge detection techniques in identifying cracks.
Surface crack detection by flash thermography on concrete surface
Cracking may impair the durability of concrete by allowing immigration of external aggressive agents; therefore, crack monitoring is always a vital part in building pathology. This study proposes to apply short-duration pulsed thermography - flash thermography (FT) - for surface crack detection. This method allows full-field and non-contact qualitative observation of thermal radiation from an object surface and is highly accepted in the aerospace industry. It is superior to the common practice of surface crack detection - visual inspection. The overall inspection time is reduced and hence maintenance costs lowered. During inspection, the inspected surface is excited with a heat-pulse of short duration (~3 ms). Surface cracking is detected based on the difference in heat emission between cracks and intact region. The results show that FT can detect surface cracks with 0.5 mm to 1 mm crack width successfully but micro-cracks (0.1 mm-0.5 mm) can only be detected by adding water with FT. In addition, this study also compared the performances of traditional Sobel and Canny edge detectors and a proposed shear image subtraction method, for crack detection. The results show that the sheared image subtraction method is significantly more effective than the other two edge detection techniques in identifying cracks.
Surface crack detection by flash thermography on concrete surface
Oberflächenrissnachweis durch Blitzthermographie auf einer Betonoberfläche
Sham, F.C. (author) / Chen, Nelson (author) / Long, Liu (author)
Insight ; 50 ; 240-243
2008
4 Seiten, 9 Bilder, 1 Tabelle, 11 Quellen
Article (Journal)
English
Application of flash thermography for crack identification in concrete materials
Tema Archive | 2010
|Simulation of the surface crack detection using inductive heated thermography
British Library Online Contents | 2012
|Crack detection of UAV concrete surface images
SPIE | 2019
|