Corrosion of rebar and role of fiber reinforced concrete
Recent studies have shown that fiber reinforcement of concrete reduces its permeability to water and enhances its service life. In this study, this finding was extended to determine if fiber reinforcement can also control corrosion of reinforcing steel in traditionally reinforced concrete. Two fiber types, cellulose and polypropylene, at 0.1 % and 0.3 % volume fraction, were examined. Two series of tests were performed. In the first series, chloride transport characteristics were determined by using the Bulk Diffusion Test, the Silver Nitrate Spray Test and the Rapid Chloride Permeability Test. In the second series, corrosion activity in reinforcing steel was monitored in loaded RC beams with and without fiber reinforcement for a year in a simulated marine environment. Results demonstrated that while the presence of fibers increased the coefficient of chloride diffusion based on total chlorides, there was a decrease in the coefficient related to free chlorides. Fibers therefore appear to bind the chlorides and inhibit their transport through concrete. Corrosion tests further corroborated these findings and indicated that fibers delayed the onset of corrosion in RC beams as long as the applied load did not exceed a certain threshold value.
Corrosion of rebar and role of fiber reinforced concrete
Recent studies have shown that fiber reinforcement of concrete reduces its permeability to water and enhances its service life. In this study, this finding was extended to determine if fiber reinforcement can also control corrosion of reinforcing steel in traditionally reinforced concrete. Two fiber types, cellulose and polypropylene, at 0.1 % and 0.3 % volume fraction, were examined. Two series of tests were performed. In the first series, chloride transport characteristics were determined by using the Bulk Diffusion Test, the Silver Nitrate Spray Test and the Rapid Chloride Permeability Test. In the second series, corrosion activity in reinforcing steel was monitored in loaded RC beams with and without fiber reinforcement for a year in a simulated marine environment. Results demonstrated that while the presence of fibers increased the coefficient of chloride diffusion based on total chlorides, there was a decrease in the coefficient related to free chlorides. Fibers therefore appear to bind the chlorides and inhibit their transport through concrete. Corrosion tests further corroborated these findings and indicated that fibers delayed the onset of corrosion in RC beams as long as the applied load did not exceed a certain threshold value.
Corrosion of rebar and role of fiber reinforced concrete
Korrosion der Armierung und Auftreten in faserverstärktem Beton
Sappakittipakorn, Manote (author) / Banthia, Nemkumar (author)
Journal of Testing and Evaluation ; 40 ; 127-136
2012
10 Seiten, 17 Bilder, 5 Tabellen, 30 Quellen
Article (Journal)
English
Corrosion of Rebar and Role of Fiber Reinforced Concrete
British Library Online Contents | 2012
|Acoustic Emission Techniques for Rebar Corrosion in Reinforced Concrete
British Library Conference Proceedings | 2007
|Field Testing of Fiber-Reinforced Polymer Rebar Reinforced Concrete Bridge Deck
British Library Conference Proceedings | 1999
|British Library Conference Proceedings | 2003
|