A platform for research: civil engineering, architecture and urbanism
Experimental Study of Post-Fire Behavior of Steel Fiber Reinforced Ceramsite Concrete Filled Steel Tubes
The axial compressive mechanical behavior of steel fiber reinforced ceramsite concrete filled steel tubes (noted as SFR-CCST) after exposure to fire are experimentally studied. Effect of furnace temperature, dosage of steel fiber in specimens on the post-fire mechanical performance of the specimens after exposure to fire was especially discussed. The results show that all the specimens of SFR-CCST have higher post-fire bearing capacity and better plastic deformation, and there was no obvious descending segment in the load-strain curves of the most specimens after exposure to fire. It was concluded that the furnace temperature applied to the specimens and dosage of steel fiber in the specimens of SFR-CCST has some effect on the post-fire mechanical performance of the ceramsite concrete-filled steel tubes after exposure to fire, and the dosage of steel fiber of 0.5% has the most effect on the post-fire performance of lightweight aggregate concrete filled steel tubes after exposure to fire.
Experimental Study of Post-Fire Behavior of Steel Fiber Reinforced Ceramsite Concrete Filled Steel Tubes
The axial compressive mechanical behavior of steel fiber reinforced ceramsite concrete filled steel tubes (noted as SFR-CCST) after exposure to fire are experimentally studied. Effect of furnace temperature, dosage of steel fiber in specimens on the post-fire mechanical performance of the specimens after exposure to fire was especially discussed. The results show that all the specimens of SFR-CCST have higher post-fire bearing capacity and better plastic deformation, and there was no obvious descending segment in the load-strain curves of the most specimens after exposure to fire. It was concluded that the furnace temperature applied to the specimens and dosage of steel fiber in the specimens of SFR-CCST has some effect on the post-fire mechanical performance of the ceramsite concrete-filled steel tubes after exposure to fire, and the dosage of steel fiber of 0.5% has the most effect on the post-fire performance of lightweight aggregate concrete filled steel tubes after exposure to fire.
Experimental Study of Post-Fire Behavior of Steel Fiber Reinforced Ceramsite Concrete Filled Steel Tubes
Zhang, Jin-Yi (author) / Wang, Xin-Tang (author) / Sun, Ping-Xin (author) / Sun, Hong-Liang (author)
2012
4 Seiten
Conference paper
English
Trans Tech Publications | 2012
|British Library Conference Proceedings | 2012
|Study of Post-Fire Performance of Steel Fiber Reinforced Ceramsite Concrete Filled Steel Tubes
British Library Conference Proceedings | 2013
|Study of Post-Fire Performance of Steel Fiber Reinforced Ceramsite Concrete Filled Steel Tubes
Trans Tech Publications | 2013
|