A platform for research: civil engineering, architecture and urbanism
Residual Strength of the CFRP- Strengthening Small Concrete Columns in Fire Situation
This paper presents the experimental results of a study carried out to investigate the performance of small scale concrete columns retrofitted with unidirectional carbon fiber-reinforced polymer (CFRP) in fire situation. This study aims at the effectiveness of CFRP through the contrast test. In order to observe the residual compressive strength, the specimen was heated to a target temperature and mechanically tested under axial compression. Other similar heated specimen was cooled down to the room temperature and mechanically tested too. This procedure was repeated by temperatures of 200 °C, 300 °C, 350 °C, 400 °C, 450 °C, 500 °C, 600 °C, 700 °C, 800 °C and 1050 °C. The heating inside the furnace was controlled in such a way that the average temperature in the furnace followed the standard time-temperature curve, ISO 834. The experimental results comproved that, due to low temperature resistance, the CFRP systems are not capable of safely and adequately enduring fire for any substantial period of time. This study evaluated a supplementary residual compressive strength of CFRP systems after cooling down to the room temperature. Finally, this study should benefit CFRP-fire research efforts by providing a similitude relationship for the testing of full-scale and small-scale specimens.
Residual Strength of the CFRP- Strengthening Small Concrete Columns in Fire Situation
This paper presents the experimental results of a study carried out to investigate the performance of small scale concrete columns retrofitted with unidirectional carbon fiber-reinforced polymer (CFRP) in fire situation. This study aims at the effectiveness of CFRP through the contrast test. In order to observe the residual compressive strength, the specimen was heated to a target temperature and mechanically tested under axial compression. Other similar heated specimen was cooled down to the room temperature and mechanically tested too. This procedure was repeated by temperatures of 200 °C, 300 °C, 350 °C, 400 °C, 450 °C, 500 °C, 600 °C, 700 °C, 800 °C and 1050 °C. The heating inside the furnace was controlled in such a way that the average temperature in the furnace followed the standard time-temperature curve, ISO 834. The experimental results comproved that, due to low temperature resistance, the CFRP systems are not capable of safely and adequately enduring fire for any substantial period of time. This study evaluated a supplementary residual compressive strength of CFRP systems after cooling down to the room temperature. Finally, this study should benefit CFRP-fire research efforts by providing a similitude relationship for the testing of full-scale and small-scale specimens.
Residual Strength of the CFRP- Strengthening Small Concrete Columns in Fire Situation
de Oliveira, Clayton Reis (author) / Lopes Moreno, Armando (author)
2013
5 Seiten
Conference paper
English
Fire Situation in Case of RC Members by Sika CFRP Strengthening
Springer Verlag | 2019
|Strengthening Square Reinforced Concrete Columns by Shape Modification and CFRP
British Library Conference Proceedings | 2013
|Strengthening of rectangular RC columns using CFRP
British Library Conference Proceedings | 2001
|