A platform for research: civil engineering, architecture and urbanism
Water permeability of concrete under uniaxial tension
Concrete structures can suffer from water permeating under stresses. This paper investigates the surface water permeability of reinforced concrete elements subjected to uniaxial tension. A testing system was developed to combine a conventional loading machine with a surface permeameter. To eliminate the effect of initial absorption of water, calibration tests were conducted on plain concrete samples with different surface saturated states. The experiment presented is designed to test the surface water permeability of a structural member under uniaxial tension. Specimens were reinforced centrally with different sizes of steel bar and fabricated with normal-strength and high-strength concrete. A uniaxial tensile load was applied from 0.10 to 0.80 of estimated ultimate cracking load in 0.10 increments. At the same time, water permeability was measured at each load step. Test results give the relationship between water permeability of concrete member and tensile load levels.
Water permeability of concrete under uniaxial tension
Concrete structures can suffer from water permeating under stresses. This paper investigates the surface water permeability of reinforced concrete elements subjected to uniaxial tension. A testing system was developed to combine a conventional loading machine with a surface permeameter. To eliminate the effect of initial absorption of water, calibration tests were conducted on plain concrete samples with different surface saturated states. The experiment presented is designed to test the surface water permeability of a structural member under uniaxial tension. Specimens were reinforced centrally with different sizes of steel bar and fabricated with normal-strength and high-strength concrete. A uniaxial tensile load was applied from 0.10 to 0.80 of estimated ultimate cracking load in 0.10 increments. At the same time, water permeability was measured at each load step. Test results give the relationship between water permeability of concrete member and tensile load levels.
Water permeability of concrete under uniaxial tension
Yuan, Yong (author) / Chi, Yang (author)
Structural Concrete ; 15 ; 191-201
2014
11 Seiten, 12 Bilder, 5 Tabellen, 20 Quellen
Article (Journal)
English
Permeability Test Method of Concrete Member under Uniaxial Tension Stress
Trans Tech Publications | 2011
|Microcrack characterization in concrete under uniaxial tension
Online Contents | 1996
|Response of Reinforced Concrete Panels under Uniaxial Tension
Online Contents | 1996
|Fracture Mechanism of Plain Concrete under Uniaxial Tension
British Library Online Contents | 1993
|Localization of Microcracking in Concrete under Uniaxial Tension
Online Contents | 1994
|