The polarization behaviour of some cold-twisted-deformed (CTD) reinforcing bars has been studied by constructing Tafel plots. The study revealed that, in the presence of millscale on the rebar, the combined effect of the ratio of cathodic/anodic area to the amount of cold working will be reflected in the polarization behaviour. In view of this, the corrosion potential shifted substancially towards the active side with a high amount of cold twisting. In the case of rebar without millscale, the corrosion potential shifted significantly towards the noble side. The cathodic process was activation-controlled for the rebars having millscale and changed to diffusion-controlled when millscale was absent. The anodic process was dissolution of iron which depends on the available anodic area. However, the anodic current density as well as anodic Tafel slope will also depend upon the nature of the corrosion. Therefore, these were high when the corrosion was localized (which may be attributed to the local acidification process) in the untwisted rebar, and decreased substantially on cold twisting when millscale was removed and the nature of the corrosion changed to general
The polarization behaviour of some cold-twisted-deformed (CTD) reinforcing bars has been studied by constructing Tafel plots. The study revealed that, in the presence of millscale on the rebar, the combined effect of the ratio of cathodic/anodic area to the amount of cold working will be reflected in the polarization behaviour. In view of this, the corrosion potential shifted substancially towards the active side with a high amount of cold twisting. In the case of rebar without millscale, the corrosion potential shifted significantly towards the noble side. The cathodic process was activation-controlled for the rebars having millscale and changed to diffusion-controlled when millscale was absent. The anodic process was dissolution of iron which depends on the available anodic area. However, the anodic current density as well as anodic Tafel slope will also depend upon the nature of the corrosion. Therefore, these were high when the corrosion was localized (which may be attributed to the local acidification process) in the untwisted rebar, and decreased substantially on cold twisting when millscale was removed and the nature of the corrosion changed to general
Polarization behaviour of corrosion-resistant CTD reinforcing bars
Polarisationsverhalten von korrosionsbeständigen kalt verformt und verdrehten (CTD) Armierungsstählen
Kumar, V. (author)
Corrosion Prevention and Control ; 43 ; 135-139
1996
5 Seiten, 4 Bilder, 2 Tabellen, 6 Quellen
Article (Journal)
English
Polarization behaviour of corrosion-resistant CTD reinforcing bars
British Library Online Contents | 1996
|Corrosion-Resistant Steel Reinforcing Bars
British Library Conference Proceedings | 1996
|Corrosion resistant concrete reinforcing bars for the marine environment
British Library Online Contents | 1997
Corrosion behaviour of new stainless steels reinforcing bars embedded in concrete
British Library Online Contents | 2007
|Stress Corrosion Behaviour of GFRP Composite Reinforcing Bars in Alkaline Environment
British Library Conference Proceedings | 2001
|