A platform for research: civil engineering, architecture and urbanism
Evaluation of Steel Corrosion in Concrete Structures Using Impact-Echo Method
The impact-echo method is commonly used for detection of flaws in concrete elements based on the shift in the thickness frequency of a plate-like member. However, there is a need to develop this efficient technique for other applications. This paper investigates the feasibility of using the impact echo-method for identifying corrosion of steel reinforcement in concrete structures. For this purpose, 180 reinforced concrete cubes were cast and tested. The main parameters studied were the amount of recycled aggregate (i.e. 0%, 25%, 50% and 100%), nanosilica (1.5% and 3%) and the steel bar diameter (12 and 20mm). Different levels of corrosion were electrochemically induced by applying impressed voltage technique for 2, 5, 10 and 15 days. The impact-echo results were correlated against the actual corrosion levels obtained by the mass loss method. The experimental results showed that the response of impact echo in terms of frequency peaks is found to be sensitive to the high and moderate levels of corrosion. However, no clear trend was observed at the initial stage of corrosion. It is demonstrated that the impact-echo testing can be effectively used to qualitatively detect the damage caused by corrosion phenomenon in reinforced concrete structures.
Evaluation of Steel Corrosion in Concrete Structures Using Impact-Echo Method
The impact-echo method is commonly used for detection of flaws in concrete elements based on the shift in the thickness frequency of a plate-like member. However, there is a need to develop this efficient technique for other applications. This paper investigates the feasibility of using the impact echo-method for identifying corrosion of steel reinforcement in concrete structures. For this purpose, 180 reinforced concrete cubes were cast and tested. The main parameters studied were the amount of recycled aggregate (i.e. 0%, 25%, 50% and 100%), nanosilica (1.5% and 3%) and the steel bar diameter (12 and 20mm). Different levels of corrosion were electrochemically induced by applying impressed voltage technique for 2, 5, 10 and 15 days. The impact-echo results were correlated against the actual corrosion levels obtained by the mass loss method. The experimental results showed that the response of impact echo in terms of frequency peaks is found to be sensitive to the high and moderate levels of corrosion. However, no clear trend was observed at the initial stage of corrosion. It is demonstrated that the impact-echo testing can be effectively used to qualitatively detect the damage caused by corrosion phenomenon in reinforced concrete structures.
Evaluation of Steel Corrosion in Concrete Structures Using Impact-Echo Method
Advanced Materials Research ; 1158 ; 147-164
2020-04-28
18 pages
Article (Journal)
Electronic Resource
English
Impact-Echo Methods to Assessment Corrosion of Reinforced Concrete Structures
Trans Tech Publications | 2014
|Using of Impact-Echo Methods to Assessment of Reinforced Concrete Structures Corrosion
Trans Tech Publications | 2013
|Monitoring of Reinforced Concrete Structure Corrosion by Using Impact-Echo Method
Trans Tech Publications | 2014
|Imaging Concrete Structures Using Air-Coupled Impact-Echo
Online Contents | 2007
|Monitoring of Reinforced Concrete Structure Corrosion by Using Impact-Echo Method
British Library Conference Proceedings | 2014
|