Seismic Response of Multistoried Building with Different Foundations Considering Interaction Effects
Current seismic design practice assumes the base of the building to be fixed and does not consider the flexibility of foundation and soil. This assumption is realistic only when the structure is founded on solid rock or when the relative stiffness of the foundation soil compared to the superstructure is high. Whereas, in reality due to natural ability of soil to deform, supporting soil medium modifies the response of the structure during earthquake to some extent. In this work the effect of soil structure interaction on seismic response of building resting on different types of foundation was studied. Present work aims to study the effect of soil structure interaction on seismic response of building resting on fixed base, pile foundation, raft foundation and combined pile-raft foundation. G+9 RCC building is analyzed for earthquake loads considered in zone III by response spectrum method and storey displacement and base shear force of building by considering and without considering SSI effect is found out by using MIDAS GEN software.
Seismic Response of Multistoried Building with Different Foundations Considering Interaction Effects
Current seismic design practice assumes the base of the building to be fixed and does not consider the flexibility of foundation and soil. This assumption is realistic only when the structure is founded on solid rock or when the relative stiffness of the foundation soil compared to the superstructure is high. Whereas, in reality due to natural ability of soil to deform, supporting soil medium modifies the response of the structure during earthquake to some extent. In this work the effect of soil structure interaction on seismic response of building resting on different types of foundation was studied. Present work aims to study the effect of soil structure interaction on seismic response of building resting on fixed base, pile foundation, raft foundation and combined pile-raft foundation. G+9 RCC building is analyzed for earthquake loads considered in zone III by response spectrum method and storey displacement and base shear force of building by considering and without considering SSI effect is found out by using MIDAS GEN software.
Seismic Response of Multistoried Building with Different Foundations Considering Interaction Effects
Applied Mechanics and Materials ; 877 ; 276-281
2018-02-15
6 pages
Article (Journal)
Electronic Resource
English
Response of Multistoried Building Considering Soil-Structural Interaction Under Lateral Loading