Reliability Assessment of Corrosion Initiation of Harbor Concrete Structure Using FOSM
Due to the uncertainty of variables in durability model, the probabilistic approach is increasing. Monte Carlo Simulation (MCS) is an easily accessible method, but requires a lot of repeated operations. This paper evaluated the effectiveness of First Order Second Moment method (FOSM), which is more convenient and time saving method than MCS, to predict the corrosion initiation in harbor concrete structure. Mean Value First Order Second Moment method (MV FOSM) and Advanced First Order Second Moment method (AFOSM) are applied to the error function solution of Fick's second law modeling chloride diffusion. Reliability index and failure probability based on MV FOSM and AFOSM are compared with the results by MCS. The comparison showed that AFOSM and MCS predict similar reliability indexes and MV FOSM underestimates the probability of corrosion initiation by chloride attack. Also, the sensitivity of variables in durability model to failure probability was evaluated on the basis of AFOSM. The results showed that AFOSM is a simple and efficient method to estimate the possibility of corrosion initiation in harbor concrete structures.
Reliability Assessment of Corrosion Initiation of Harbor Concrete Structure Using FOSM
Due to the uncertainty of variables in durability model, the probabilistic approach is increasing. Monte Carlo Simulation (MCS) is an easily accessible method, but requires a lot of repeated operations. This paper evaluated the effectiveness of First Order Second Moment method (FOSM), which is more convenient and time saving method than MCS, to predict the corrosion initiation in harbor concrete structure. Mean Value First Order Second Moment method (MV FOSM) and Advanced First Order Second Moment method (AFOSM) are applied to the error function solution of Fick's second law modeling chloride diffusion. Reliability index and failure probability based on MV FOSM and AFOSM are compared with the results by MCS. The comparison showed that AFOSM and MCS predict similar reliability indexes and MV FOSM underestimates the probability of corrosion initiation by chloride attack. Also, the sensitivity of variables in durability model to failure probability was evaluated on the basis of AFOSM. The results showed that AFOSM is a simple and efficient method to estimate the possibility of corrosion initiation in harbor concrete structures.
Reliability Assessment of Corrosion Initiation of Harbor Concrete Structure Using FOSM
Key Engineering Materials ; 385-387 ; 621-624
2008-07-02
4 pages
Article (Journal)
Electronic Resource
English
Corrosion , Durability , FOSM , Reliability
Reliability Assessment of Corrosion Initiation of Harbor Concrete Structure Using FOSM
British Library Online Contents | 2008
|Seismic demand sensitivity of reinforced concrete shear-wall building using FOSM method
Online Contents | 2005
|Liquefaction Mapping of Kolkata City Using FOSM Method
Springer Verlag | 2022
|A new seismic hazard analysis using FOSM algorithms
Online Contents | 2014
|