Seismic Performance Improvement of Precast Buildings Using Dissipative Friction Devices
This study presents an innovative approach to enhance the seismic performance of precast structures. Friction devices were inserted at the beam-to-column connections with the aim of providing supplemental energy dissipation and structural drift control. A single-story industrial building and a multi-story frame were analyzed in this study to assess the effectiveness of the dissipative friction devices. A simplified model describing the hysteretic behaviour of the friction device was developed and parametric analyses were carried out in order to establish the optimum value of the plastic moment of the device for the different precast structures. The results of the numerical investigations showed that the installation of the friction devices caused a significant decrease of displacements at the top of the structures. The energy dissipation mostly concentrated in the devices and the plastic demand on structural members was considerably reduced, along with the potential for structural damage.
Seismic Performance Improvement of Precast Buildings Using Dissipative Friction Devices
This study presents an innovative approach to enhance the seismic performance of precast structures. Friction devices were inserted at the beam-to-column connections with the aim of providing supplemental energy dissipation and structural drift control. A single-story industrial building and a multi-story frame were analyzed in this study to assess the effectiveness of the dissipative friction devices. A simplified model describing the hysteretic behaviour of the friction device was developed and parametric analyses were carried out in order to establish the optimum value of the plastic moment of the device for the different precast structures. The results of the numerical investigations showed that the installation of the friction devices caused a significant decrease of displacements at the top of the structures. The energy dissipation mostly concentrated in the devices and the plastic demand on structural members was considerably reduced, along with the potential for structural damage.
Seismic Performance Improvement of Precast Buildings Using Dissipative Friction Devices
Applied Mechanics and Materials ; 256-259 ; 2229-2233
2012-12-13
5 pages
Article (Journal)
Electronic Resource
English
Seismic Performance Improvement of Precast Buildings Using Dissipative Friction Devices
Tema Archive | 2012
|Seismic Performance Improvement of Precast Buildings Using Dissipative Friction Devices
British Library Conference Proceedings | 2012
|Friction dissipative devices for cladding panels in precast buildings
Taylor & Francis Verlag | 2011
|Friction-based dissipative devices for precast concrete panels
Elsevier | 2017
|