A platform for research: civil engineering, architecture and urbanism
Evaluation of Multiple Corrrosion Protection Systems and Corrosion Inhibitors for Reinforced Concrete Bridge Decks
The corrosion performance of different corrosion protection systems is evaluated using the mortar-wrapped rapid macrocell test, bench-scale tests (the Southern Exposure, cracked beam, and ASTM G109 tests), and field tests. The results indicate that a reduced water-cement ratio improves the corrosion resistance of conventional steel in uncracked concrete. The use of a corrosion inhibitor improves the corrosion resistance of conventional steel in both cracked and uncracked concrete, but provides only a very limited improvement in the corrosion resistance of epoxy-coated reinforcement. Increased adhesion between the epoxy coating and reinforcing steel provides no improvement in the corrosion resistance of epoxy-coated reinforcement. The corrosion losses for multiple-coated reinforcement are comparable with those of conventional epoxy-coated reinforcement. Pickled 2205 stainless steel demonstrates excellent corrosion resistance. ECR, ECR with increased adhesion, and pickled 2205 stainless steel are the most cost-effective corrosion protection systems based on the economic analyses of a 216-mm (8.5-in.) thick bridge deck over a 75-year design life.
Evaluation of Multiple Corrrosion Protection Systems and Corrosion Inhibitors for Reinforced Concrete Bridge Decks
The corrosion performance of different corrosion protection systems is evaluated using the mortar-wrapped rapid macrocell test, bench-scale tests (the Southern Exposure, cracked beam, and ASTM G109 tests), and field tests. The results indicate that a reduced water-cement ratio improves the corrosion resistance of conventional steel in uncracked concrete. The use of a corrosion inhibitor improves the corrosion resistance of conventional steel in both cracked and uncracked concrete, but provides only a very limited improvement in the corrosion resistance of epoxy-coated reinforcement. Increased adhesion between the epoxy coating and reinforcing steel provides no improvement in the corrosion resistance of epoxy-coated reinforcement. The corrosion losses for multiple-coated reinforcement are comparable with those of conventional epoxy-coated reinforcement. Pickled 2205 stainless steel demonstrates excellent corrosion resistance. ECR, ECR with increased adhesion, and pickled 2205 stainless steel are the most cost-effective corrosion protection systems based on the economic analyses of a 216-mm (8.5-in.) thick bridge deck over a 75-year design life.
Evaluation of Multiple Corrrosion Protection Systems and Corrosion Inhibitors for Reinforced Concrete Bridge Decks
Xing, Lihua (author)
2010
Theses
Electronic Resource
English
Cathodic Protection for Reinforced Concrete Bridge Decks
NTIS | 1991
|Chloride-induced corrosion of reinforced concrete bridge decks
British Library Online Contents | 2002
|