Monitoring of compressive strength gain in mass concrete using embedded piezoelectric transducers
AbstractThis study extended the electromechanical impedance (EMI) technique to monitor the 28‐day age of strength gain in mass concrete, although it has been validated in strength monitoring of a lab‐scaled concrete specimen. Embedded piezoelectric (PZT) transducer, namely, aluminum embedded PZT (AEP), that was wrapped by two sandwich aluminum pastes was proposed for EMI monitoring. The workability of the AEP was first verified via finite element analysis, where the effect of hydration heat on the EMI signature of the AEP was evaluated via numerical modeling and prior thermal test. In the experiment, totally four AEP transducers arranged at different loci were applied to monitor strength gain in a mass concrete specimen. As a comparison, the maturity method was also performed to estimate the strength of the specimen. Characteristics of EMI signature and its statistical indices including root mean square deviation (RMSD) and mean absolute percentage deviation (MAPD) were analyzed and correlated to strength development in mass concrete. Monitoring results indicated that the AEP transducers were capable of identifying the strength gain of mass concrete. The logarithmic function between the RMSD/MAPD index values and compressive strength perfectly predicted the strength development, which could be further employed for real‐life and in situ applications.
Monitoring of compressive strength gain in mass concrete using embedded piezoelectric transducers
AbstractThis study extended the electromechanical impedance (EMI) technique to monitor the 28‐day age of strength gain in mass concrete, although it has been validated in strength monitoring of a lab‐scaled concrete specimen. Embedded piezoelectric (PZT) transducer, namely, aluminum embedded PZT (AEP), that was wrapped by two sandwich aluminum pastes was proposed for EMI monitoring. The workability of the AEP was first verified via finite element analysis, where the effect of hydration heat on the EMI signature of the AEP was evaluated via numerical modeling and prior thermal test. In the experiment, totally four AEP transducers arranged at different loci were applied to monitor strength gain in a mass concrete specimen. As a comparison, the maturity method was also performed to estimate the strength of the specimen. Characteristics of EMI signature and its statistical indices including root mean square deviation (RMSD) and mean absolute percentage deviation (MAPD) were analyzed and correlated to strength development in mass concrete. Monitoring results indicated that the AEP transducers were capable of identifying the strength gain of mass concrete. The logarithmic function between the RMSD/MAPD index values and compressive strength perfectly predicted the strength development, which could be further employed for real‐life and in situ applications.
Monitoring of compressive strength gain in mass concrete using embedded piezoelectric transducers
Structural Design Tall Build
Ai, Demi (author) / Chen, Chaokun (author) / Zhu, Hongping (author)
2024-11-01
Article (Journal)
Electronic Resource
English
Concrete early-age strength monitoring using embedded piezoelectric transducers
British Library Online Contents | 2006
|Online monitoring of cracking in concrete structures using embedded piezoelectric transducers
British Library Online Contents | 2014
|Monitoring of cement hydration using embedded piezoelectric transducers
British Library Online Contents | 2008
|