A platform for research: civil engineering, architecture and urbanism
A Repairable Connection for Earthquake‐Resisting Moment Frames
ABSTRACTMost steel moment frames are designed so that the beams act as structural fuses during earthquake loading. This approach, while effective for life safety, has poor resilience because it is difficult to replace beams in a building. A repairable steel moment frame connection has been developed that may be attractive to engineers and constructors. The connection has a fuse plate bolted to the beam bottom flange which experiences shear yielding during severe earthquakes, protecting both the column and the beam. After an earthquake, the fuse plates can be removed and replaced to unlock residual frame deformations and prepare the building for another event.Full‐scale experiments were conducted to validate the performance of this repairable connection. Two tests were performed with a W690×125 beam and a W530×196 column. The tests demonstrated rotation capacities of at least 0.05 rad, which exceeded AISC requirements for special moment frames. The fuse plate was effective in preventing beam damage in each test, and the second test demonstrated that the connection could be repaired by replacing the fuse plate.
A Repairable Connection for Earthquake‐Resisting Moment Frames
ABSTRACTMost steel moment frames are designed so that the beams act as structural fuses during earthquake loading. This approach, while effective for life safety, has poor resilience because it is difficult to replace beams in a building. A repairable steel moment frame connection has been developed that may be attractive to engineers and constructors. The connection has a fuse plate bolted to the beam bottom flange which experiences shear yielding during severe earthquakes, protecting both the column and the beam. After an earthquake, the fuse plates can be removed and replaced to unlock residual frame deformations and prepare the building for another event.Full‐scale experiments were conducted to validate the performance of this repairable connection. Two tests were performed with a W690×125 beam and a W530×196 column. The tests demonstrated rotation capacities of at least 0.05 rad, which exceeded AISC requirements for special moment frames. The fuse plate was effective in preventing beam damage in each test, and the second test demonstrated that the connection could be repaired by replacing the fuse plate.
A Repairable Connection for Earthquake‐Resisting Moment Frames
ce papers
Richards, Paul W. (author)
ce/papers ; 3 ; 457-462
2019-09-01
Article (Journal)
Electronic Resource
English
Moment redistribution for earthquake design of reinforced concrete moment-resisting frames
British Library Conference Proceedings | 2010
|Fire after earthquake analysis of steel moment resisting frames
Springer Verlag | 2009
|Post-earthquake fire resistance of moment resisting steel frames
British Library Online Contents | 2003
|