A platform for research: civil engineering, architecture and urbanism
Multiresponse optimization of exhaust thermoelectric generator using Taguchi‐based gray relation analysis
The best operating condition of the exhaust thermoelectric generator (ETEG) provides more power output and low‐pressure drop (low‐PD). So it is required to optimize the operating condition of the ETEG. In the present work, Taguchi's L18(61 33) orthogonal array was chosen to find the optimal parameters. Analysis of variance was used to determine the percent contribution of the control factors such as engine loads (ELs), different types of heat exchangers (HEs) with and without inserts, water flow rate (WFR), and external load resistance (ELR) on the thermoelectric power output and PD in the HE. The confirmation test was carried out at optimum levels for the regression equations and Taguchi method. Gray relational analysis was performed to find the optimum value of the power output and PD. It is observed that the optimal operating condition is EL6 HE1 WFR3 ELR2 (EL6 = 10 kg, HE1 = G‐type test section, WFR3 = 0.08 kg/s, and ELR2 = 40 Ω).
Multiresponse optimization of exhaust thermoelectric generator using Taguchi‐based gray relation analysis
The best operating condition of the exhaust thermoelectric generator (ETEG) provides more power output and low‐pressure drop (low‐PD). So it is required to optimize the operating condition of the ETEG. In the present work, Taguchi's L18(61 33) orthogonal array was chosen to find the optimal parameters. Analysis of variance was used to determine the percent contribution of the control factors such as engine loads (ELs), different types of heat exchangers (HEs) with and without inserts, water flow rate (WFR), and external load resistance (ELR) on the thermoelectric power output and PD in the HE. The confirmation test was carried out at optimum levels for the regression equations and Taguchi method. Gray relational analysis was performed to find the optimum value of the power output and PD. It is observed that the optimal operating condition is EL6 HE1 WFR3 ELR2 (EL6 = 10 kg, HE1 = G‐type test section, WFR3 = 0.08 kg/s, and ELR2 = 40 Ω).
Multiresponse optimization of exhaust thermoelectric generator using Taguchi‐based gray relation analysis
Patil, Dipak S. (author)
Heat Transfer ; 52 ; 2514-2537
2023-05-01
24 pages
Article (Journal)
Electronic Resource
English
Thermal Optimization of Exhaust-Based Thermoelectric Generator
British Library Online Contents | 2013
|Optimization of Lightweight Concrete Process by Gray-Taguchi Method
British Library Online Contents | 2015
|Optimization of Lightweight Concrete Process by Gray-Taguchi Method
Online Contents | 2014
|Study of Multiresponse Optimization for Fiber-reinforced Poly(Butylene Terephthalate)
British Library Online Contents | 2005
|