A platform for research: civil engineering, architecture and urbanism
Application and testing of plastic fibre reinforced dry‐mix shotcrete / Einsatz und Prüfung von kunststofffaserbewehrtem Trockenspritzbeton
The Conrad Observatory in the state of Lower Austria is a geophysical research and development facility of the Central Institute for Meteorology and Geodynamics (ZAMG). The isolation of the tunnel system fulfils the optimal requirements for high‐precision measurements. The client specified shotcrete class EV700 for the plastic fibre‐reinforced shotcrete, i.e. the test bodies have to show an energy absorption capacity of at least 700 J in the slab test. The quality verification for the suitability of a fibre‐reinforced shotcrete is performed according to the ÖVBB guideline “Sprayed Concrete” with a slab test as defined in the Austrian standard ÖNORM EN 14488‐5, which can determine the energy absorption capacity and assign the shotcrete to an energy absorption class. The test rig used at the Chair of Subsurface Engineering is described, together with test results from different plastic fibre shotcretes from various testing institutes.
Das Conrad Observatorium in Niederösterreich ist eine geophysikalische Forschungs‐ und Entwicklungseinrichtung der Zentralanstalt für Meteorologie und Geodynamik (ZAMG). Die Abgeschiedenheit des Stollensystems erfüllt in optimaler Weise die für die hochpräzisen Messungen notwendigen Anforderungen. Auftraggeberseitig wurde für den kunststofffaserbewehrten Spritzbeton die Spritzbetonklasse EV700 vorgegeben, d.h., im Plattenversuch muss ein Energieabsorptionsvermögen von jeweils mindestens 700 J erzielt werden. Der Qualitätsnachweis für die Eignung eines faserbewehrten Spritzbetons erfolgt nach ÖVBB‐Richtlinie Spritzbeton durch den in ÖNORM EN 14488‐5 definierten Plattenversuch, mit dem die Energieabsorptionskapazität ermittelt und der Spritzbeton einer Energieabsorptionsklasse zugeordnet werden kann. Der am Lehrstuhl für Subsurface Engineering eingesetzte Versuchsaufbau wird vorgestellt, zusammen mit Prüfergebnissen von unterschiedlichen Kunststofffaserspritzbetonen von verschiedenen Prüfinstitutionen.
Application and testing of plastic fibre reinforced dry‐mix shotcrete / Einsatz und Prüfung von kunststofffaserbewehrtem Trockenspritzbeton
The Conrad Observatory in the state of Lower Austria is a geophysical research and development facility of the Central Institute for Meteorology and Geodynamics (ZAMG). The isolation of the tunnel system fulfils the optimal requirements for high‐precision measurements. The client specified shotcrete class EV700 for the plastic fibre‐reinforced shotcrete, i.e. the test bodies have to show an energy absorption capacity of at least 700 J in the slab test. The quality verification for the suitability of a fibre‐reinforced shotcrete is performed according to the ÖVBB guideline “Sprayed Concrete” with a slab test as defined in the Austrian standard ÖNORM EN 14488‐5, which can determine the energy absorption capacity and assign the shotcrete to an energy absorption class. The test rig used at the Chair of Subsurface Engineering is described, together with test results from different plastic fibre shotcretes from various testing institutes.
Das Conrad Observatorium in Niederösterreich ist eine geophysikalische Forschungs‐ und Entwicklungseinrichtung der Zentralanstalt für Meteorologie und Geodynamik (ZAMG). Die Abgeschiedenheit des Stollensystems erfüllt in optimaler Weise die für die hochpräzisen Messungen notwendigen Anforderungen. Auftraggeberseitig wurde für den kunststofffaserbewehrten Spritzbeton die Spritzbetonklasse EV700 vorgegeben, d.h., im Plattenversuch muss ein Energieabsorptionsvermögen von jeweils mindestens 700 J erzielt werden. Der Qualitätsnachweis für die Eignung eines faserbewehrten Spritzbetons erfolgt nach ÖVBB‐Richtlinie Spritzbeton durch den in ÖNORM EN 14488‐5 definierten Plattenversuch, mit dem die Energieabsorptionskapazität ermittelt und der Spritzbeton einer Energieabsorptionsklasse zugeordnet werden kann. Der am Lehrstuhl für Subsurface Engineering eingesetzte Versuchsaufbau wird vorgestellt, zusammen mit Prüfergebnissen von unterschiedlichen Kunststofffaserspritzbetonen von verschiedenen Prüfinstitutionen.
Application and testing of plastic fibre reinforced dry‐mix shotcrete / Einsatz und Prüfung von kunststofffaserbewehrtem Trockenspritzbeton
Pittino, Gerhard (author) / Galler, Robert (author) / Mößlacher, Andreas (author) / Schwab, Peter (author)
Geomechanics and Tunnelling ; 4 ; 63-69
2011-02-01
7 pages
Article (Journal)
Electronic Resource
English
Application and testing of plastic fibre reinforced dry-mix shotcrete