A platform for research: civil engineering, architecture and urbanism
Seismic behaviour of composite steel‐concrete shear walls with central openings
Reinforced concrete shear walls are the most effective structural elements used to increase the overall lateral stiffness and deformation capacity of multi‐storey buildings structures. Due to the functional or architectural requirements, structural walls with multiple openings have to be frequently designed. This fact, impose to assure higher sectional strength of the structural elements, which have reduced the cross‐sections due to openings. Composite steel‐concrete shear walls, with steel embedded profiles, could represent alternative structural solutions to increase overall performances of such walls. This paper presents an experimental study made on three composite steel‐concrete shear walls with central openings and partially embedded steel profiles. The experimental specimens were built to 1:3 reduced scale and present different cross‐sectional arrangements. The walls were subjected to quasi‐static reversed lateral and vertical loads with the aim to analyse the nonlinear behaviour of elements. The behaviour of elements was monitored in terms of crack distribution to identify the failure stages, maximum load and lateral displacements. From the tested elements, the specimen which had hooked steel fibres embedded in the concrete attained the highest ductility, proving that the fibres contribute at the dissipation of energy from earthquakes.
Seismic behaviour of composite steel‐concrete shear walls with central openings
Reinforced concrete shear walls are the most effective structural elements used to increase the overall lateral stiffness and deformation capacity of multi‐storey buildings structures. Due to the functional or architectural requirements, structural walls with multiple openings have to be frequently designed. This fact, impose to assure higher sectional strength of the structural elements, which have reduced the cross‐sections due to openings. Composite steel‐concrete shear walls, with steel embedded profiles, could represent alternative structural solutions to increase overall performances of such walls. This paper presents an experimental study made on three composite steel‐concrete shear walls with central openings and partially embedded steel profiles. The experimental specimens were built to 1:3 reduced scale and present different cross‐sectional arrangements. The walls were subjected to quasi‐static reversed lateral and vertical loads with the aim to analyse the nonlinear behaviour of elements. The behaviour of elements was monitored in terms of crack distribution to identify the failure stages, maximum load and lateral displacements. From the tested elements, the specimen which had hooked steel fibres embedded in the concrete attained the highest ductility, proving that the fibres contribute at the dissipation of energy from earthquakes.
Seismic behaviour of composite steel‐concrete shear walls with central openings
Todea, Viorel (author) / Dan, Daniel (author) / Stoian, Valeriu (author) / Florut, Sorin‐Codrut (author) / Popescu, Dan‐Adrian (author)
ce/papers ; 4 ; 1844-1848
2021-09-01
5 pages
Article (Journal)
Electronic Resource
English
The Seismic Behaviour of Composite Steel-Concrete Coupled Walls with Centred Openings
Springer Verlag | 2022
|Seismic Behaviour of Steel Plate Shear Walls with Door and Window Sized Openings
Springer Verlag | 2022
|Seismic behaviour of lightly reinforced concrete structural walls with openings
Online Contents | 2015
|Nonlinear seismic response analysis method of reinforced concrete shear walls with openings
British Library Online Contents | 2005
|Seismic behaviour of concrete shear walls
NTIS | 1989
|