Shake table tests on standard and innovative temporary partition walls
Shake table tests are performed on temporary internal partitions for office buildings. Four different specimens are tested. A steel frame is designed to exhibit relative displacements which typically occur at a given story of ordinary buildings. Four different partition walls are tested simultaneously for each specimen typology. This allows investigating the influence of an innovative device on the seismic performance of the tested components. The innovative device avoids the unhooking of the panels from the supporting studs. Several shake table tests are performed subjecting the specimens to interstory drift ratios up to 1.57%. Both the hysteretic curves and the natural frequency trend highlight that the partitions do not contribute to the lateral stiffness of the test setup. The damping ratio increases after the partition walls are installed within the test frame, causing a beneficial effect in the dynamic response. Minor damage state occurs for interstory drift ratio (IDR) in the range 0.41–0.65% in standard specimens, whereas moderate and major damage states are attained for IDR in the range 0.51–0.95%. Significant increase of collapse IDR is recorded with the introduction of the innovative device, up to IDR larger than 1.45%. It can be therefore concluded that a simple innovative device is defined, which significantly improves the seismic performance of the tested specimen. Copyright © 2017 John Wiley & Sons, Ltd.
Shake table tests on standard and innovative temporary partition walls
Shake table tests are performed on temporary internal partitions for office buildings. Four different specimens are tested. A steel frame is designed to exhibit relative displacements which typically occur at a given story of ordinary buildings. Four different partition walls are tested simultaneously for each specimen typology. This allows investigating the influence of an innovative device on the seismic performance of the tested components. The innovative device avoids the unhooking of the panels from the supporting studs. Several shake table tests are performed subjecting the specimens to interstory drift ratios up to 1.57%. Both the hysteretic curves and the natural frequency trend highlight that the partitions do not contribute to the lateral stiffness of the test setup. The damping ratio increases after the partition walls are installed within the test frame, causing a beneficial effect in the dynamic response. Minor damage state occurs for interstory drift ratio (IDR) in the range 0.41–0.65% in standard specimens, whereas moderate and major damage states are attained for IDR in the range 0.51–0.95%. Significant increase of collapse IDR is recorded with the introduction of the innovative device, up to IDR larger than 1.45%. It can be therefore concluded that a simple innovative device is defined, which significantly improves the seismic performance of the tested specimen. Copyright © 2017 John Wiley & Sons, Ltd.
Shake table tests on standard and innovative temporary partition walls
Petrone, Crescenzo (author) / Magliulo, Gennaro (author) / Manfredi, Gaetano (author)
Earthquake Engineering & Structural Dynamics ; 46 ; 1599-1624
2017-08-01
26 pages
Article (Journal)
Electronic Resource
English
Shake Table Tests on FRP-Rehabilitated RC Shear Walls
Online Contents | 2013
|Shake Table Tests on FRP-Rehabilitated RC Shear Walls
British Library Online Contents | 2013
|Shake Table Tests on FRP-Rehabilitated RC Shear Walls
ASCE | 2012
|Shake table tests for caisson-type quay walls retrofitted by geogrids
British Library Conference Proceedings | 2006
|