Volatile Organic Compound Stripping at Clarifier Weirs
Volatile organic compound (VOC) stripping at clarifier weirs was investigated for both clean water and primary wastewater using a pilot‐scale model with a cross‐sectional geometry similar to clarifier weirs. Drop height, type of flow regime over the weir, and weir shape were identified as important parameters influencing mass transfer. It was also observed that VOC stripping from free‐fall flow could be correlated with Henry's law constant. A model that accounts for liquid‐ and gas‐phase mass transfer was developed to predict VOC stripping from clean water. The relatively low and consistent gas‐ and liquid‐phase mass‐transfer coefficients used in the model suggest that a representative value may apply for all weir conditions. Incorporating a transition coefficient between clean water and wastewater made it possible to predict VOC transfer in primary wastewater based on clean water data. Experimental results and modeling efforts described in this paper could serve as a first step in estimating VOC emissions for flows over clarifiers at wastewater treatment plants.
Volatile Organic Compound Stripping at Clarifier Weirs
Volatile organic compound (VOC) stripping at clarifier weirs was investigated for both clean water and primary wastewater using a pilot‐scale model with a cross‐sectional geometry similar to clarifier weirs. Drop height, type of flow regime over the weir, and weir shape were identified as important parameters influencing mass transfer. It was also observed that VOC stripping from free‐fall flow could be correlated with Henry's law constant. A model that accounts for liquid‐ and gas‐phase mass transfer was developed to predict VOC stripping from clean water. The relatively low and consistent gas‐ and liquid‐phase mass‐transfer coefficients used in the model suggest that a representative value may apply for all weir conditions. Incorporating a transition coefficient between clean water and wastewater made it possible to predict VOC transfer in primary wastewater based on clean water data. Experimental results and modeling efforts described in this paper could serve as a first step in estimating VOC emissions for flows over clarifiers at wastewater treatment plants.
Volatile Organic Compound Stripping at Clarifier Weirs
Zytner, R.G. (author) / Rahmé, Z.G. (author) / Corsi, R.L. (author) / Labocha, M. (author) / Parker, W. (author)
Water Environment Research ; 71 ; 1188-1196
1999-09-01
9 pages
Article (Journal)
Electronic Resource
English
Parameters influencing oxygen uptake at clarifier weirs
Wiley | 1996
|Redesigning Compound Weirs as Polynomial Weirs
ASCE | 2019
|Experimental Investigation of using the Piano Key Weirs in the Outlet of the Clarifier Structure
DOAJ | 2023
|Chain weirs, chain-needle weirs and self-opening chain-needle weirs