Effects of fire location on the capacity of smoke exhaust from natural ventilation shafts in urban tunnels
Investigation of natural ventilation using shafts in tunnels has been receiving more attentions; however, analyses on how fire position influences the natural ventilation performance have rarely been addressed. This study investigated the influence of different fire positions between two shafts on natural ventilation effectiveness in a tunnel by large eddy simulation. The smoke movement characteristics were studied in detail, with systematically varying the fire position between two shafts and the longitudinal wind speed in the tunnel. The typical smoke characteristic parameters, such as temperature distribution, mass flow rate and CO concentration were emphatically investigated. Some special phenomena, such as plug‐holing and smoke bifurcation, were also discussed.
Effects of fire location on the capacity of smoke exhaust from natural ventilation shafts in urban tunnels
Investigation of natural ventilation using shafts in tunnels has been receiving more attentions; however, analyses on how fire position influences the natural ventilation performance have rarely been addressed. This study investigated the influence of different fire positions between two shafts on natural ventilation effectiveness in a tunnel by large eddy simulation. The smoke movement characteristics were studied in detail, with systematically varying the fire position between two shafts and the longitudinal wind speed in the tunnel. The typical smoke characteristic parameters, such as temperature distribution, mass flow rate and CO concentration were emphatically investigated. Some special phenomena, such as plug‐holing and smoke bifurcation, were also discussed.
Effects of fire location on the capacity of smoke exhaust from natural ventilation shafts in urban tunnels
Fan, Chuangang (author) / Chen, Jian (author) / Zhou, Yang (author) / Liu, Xiaoping (author)
Fire and Materials ; 42 ; 974-984
2018-12-01
11 pages
Article (Journal)
Electronic Resource
English
SMOKE VENTILATION OF FIRE FIGHTING SHAFTS
British Library Online Contents | 2003
|Risks to fire-fighters? Issues relating to smoke shafts and the ventilation of fire-fighting shafts
British Library Online Contents | 1999
|Underground building natural lighting, daily ventilation, fire smoke exhaust device
European Patent Office | 2015
|