A platform for research: civil engineering, architecture and urbanism
Shaking table tests on seismic response of steel braced frames with column uplift
10.1002/eqe.603.abs
Previous studies have suggested that rocking vibration accompanied by uplift motion might reduce the seismic damage to buildings subjected to severe earthquake motions. This paper reports on the use of shaking table tests and numerical analyses to evaluate and compare the seismic response of base‐plate‐yielding rocking systems with columns allowed to uplift with that of fixed‐base systems. The study is performed using half‐scale three‐storey, 1 × 2 bay braced steel frames with a total height of 5.3 m. Base plates that yield due to column tension were installed at the base of each column. Two types of base plates with different thicknesses are investigated. The earthquake ground motion used for the tests and analyses is the record of the 1940 El Centro NS component with the time scale shortened by a factor of 1/√2. The maximum input acceleration is scaled to examine the structural response at various earthquake intensities. The column base shears in the rocking frames with column uplift are reduced by up to 52% as compared to the fixed‐base frames. Conversely, the maximum roof displacements of the fixed and rocking frames are about the same. It is also noted that the effect of the vertical impact on the column associated with touchdown of the base plate is small because the difference in tensile and compressive forces is primarily due to the self‐limiting tensile force in the column caused by yielding of the base plate. Copyright © 2006 John Wiley & Sons, Ltd.
Shaking table tests on seismic response of steel braced frames with column uplift
10.1002/eqe.603.abs
Previous studies have suggested that rocking vibration accompanied by uplift motion might reduce the seismic damage to buildings subjected to severe earthquake motions. This paper reports on the use of shaking table tests and numerical analyses to evaluate and compare the seismic response of base‐plate‐yielding rocking systems with columns allowed to uplift with that of fixed‐base systems. The study is performed using half‐scale three‐storey, 1 × 2 bay braced steel frames with a total height of 5.3 m. Base plates that yield due to column tension were installed at the base of each column. Two types of base plates with different thicknesses are investigated. The earthquake ground motion used for the tests and analyses is the record of the 1940 El Centro NS component with the time scale shortened by a factor of 1/√2. The maximum input acceleration is scaled to examine the structural response at various earthquake intensities. The column base shears in the rocking frames with column uplift are reduced by up to 52% as compared to the fixed‐base frames. Conversely, the maximum roof displacements of the fixed and rocking frames are about the same. It is also noted that the effect of the vertical impact on the column associated with touchdown of the base plate is small because the difference in tensile and compressive forces is primarily due to the self‐limiting tensile force in the column caused by yielding of the base plate. Copyright © 2006 John Wiley & Sons, Ltd.
Shaking table tests on seismic response of steel braced frames with column uplift
Midorikawa, Mitsumasa (author) / Azuhata, Tatsuya (author) / Ishihara, Tadashi (author) / Wada, Akira (author)
Earthquake Engineering & Structural Dynamics ; 35 ; 1767-1785
2006-11-25
20 pages
Article (Journal)
Electronic Resource
English
Shaking table tests on seismic response of steel braced frames with column uplift
Online Contents | 2006
|Shaking table earthquake response of medium-rise knee braced frames
British Library Conference Proceedings | 1995
|The effects of foundation uplift on seismic response of diagonally braced steel frames
Springer Verlag | 2020
|The effects of foundation uplift on seismic response of diagonally braced steel frames
Springer Verlag | 2020
|Steel braced frames: enhancing seismic response
British Library Online Contents | 2009