Abstract: The typhoon behavior and performance of a tuned mass damper (TMD) are presented based on the system identification and the inverse modal wind load estimation. The TMD was installed on a 39‐story, 184.6‐m steel building located in Incheon, Korea with a monitoring system consisting of an anemometer, accelerometers, and internet‐based data logging system. On September 2, 2010, the building experienced the Kompasu Typhoon, in which the peak wind speed, measured by an anemometer installed on the roof floor, was 49.7 m/s. To analyze the behavior of the building during the typhoon, the dynamic properties of building and TMD are identified from the measured responses. The modal wind load is then inversely estimated from the TMD and building accelerations using a Kalman filter, and the vibration reduction performance of the TMD is evaluated. The analysis results show that the typhoon‐induced vibration was reduced significantly due to the installation of TMD.
Performance Evaluation of TMD under Typhoon Using System Identification and Inverse Wind Load Estimation
Abstract: The typhoon behavior and performance of a tuned mass damper (TMD) are presented based on the system identification and the inverse modal wind load estimation. The TMD was installed on a 39‐story, 184.6‐m steel building located in Incheon, Korea with a monitoring system consisting of an anemometer, accelerometers, and internet‐based data logging system. On September 2, 2010, the building experienced the Kompasu Typhoon, in which the peak wind speed, measured by an anemometer installed on the roof floor, was 49.7 m/s. To analyze the behavior of the building during the typhoon, the dynamic properties of building and TMD are identified from the measured responses. The modal wind load is then inversely estimated from the TMD and building accelerations using a Kalman filter, and the vibration reduction performance of the TMD is evaluated. The analysis results show that the typhoon‐induced vibration was reduced significantly due to the installation of TMD.
Performance Evaluation of TMD under Typhoon Using System Identification and Inverse Wind Load Estimation
Kang, Namcheol (author) / Kim, Hongjin (author) / Choi & Seongwoo Jo, Sunyoung (author) / Hwang, Jae‐Seung (author) / Yu, Eunjong (author)
Computer‐Aided Civil and Infrastructure Engineering ; 27 ; 455-473
2012-07-01
19 pages
Article (Journal)
Electronic Resource
English
Wind load identification using wind tunnel test data by inverse analysis
Online Contents | 2011
|Wiley | 2013
|Nonlinear structural system wind load input estimation using the extended inverse method
Online Contents | 2013
|Directional wind speed evaluation in mixed wind climates using modified typhoon simulation method
British Library Conference Proceedings | 2005
|