A platform for research: civil engineering, architecture and urbanism
Effectiveness of sliding isolators with variable curvature in near‐fault ground motions
Recent studies have revealed that a sliding isolator with variable curvature (SIVC) can mitigate the resonance phenomenon likely to occur in seismic response of a conventional friction pendulum system (FPS) isolator due to its constant isolation frequency. The present study simulates four SIVC isolators and an FPS to find the optimum range of initial isolation period and coefficient of friction and employ them in comparing the effectiveness of SIVC in different peak ground acceleration (PGA) scales of near‐fault earthquakes. Velocity‐dependent coefficient of friction and modified viscoplasticity model have been used to simulate nonlinear friction force of the isolators. Results indicate identical performance of all SIVC isolators in PGA scales up to 0.4 g. When subjected to PGA scales from 0.4 g to 1.0 g, polynomial friction pendulum isolator (PFPI) and variable curvature friction pendulum system (VCFPS) reduce base displacement greatly, while conical friction pendulum isolator (CFPI) and variable frequency pendulum isolator (VFPI) show amplified responses. However, in mitigating structural acceleration, performance of CFPI and VFPI, unlike PFPI and VCFPS, which perform poorly, is excellent. Thus, in a strong near‐fault earthquake, PFPI and VCFPS or CFPI and VFPI can be chosen based on whether reduction of base displacement or super‐structural acceleration is the main concern of designer, respectively. Copyright © 2015 John Wiley & Sons, Ltd.
Effectiveness of sliding isolators with variable curvature in near‐fault ground motions
Recent studies have revealed that a sliding isolator with variable curvature (SIVC) can mitigate the resonance phenomenon likely to occur in seismic response of a conventional friction pendulum system (FPS) isolator due to its constant isolation frequency. The present study simulates four SIVC isolators and an FPS to find the optimum range of initial isolation period and coefficient of friction and employ them in comparing the effectiveness of SIVC in different peak ground acceleration (PGA) scales of near‐fault earthquakes. Velocity‐dependent coefficient of friction and modified viscoplasticity model have been used to simulate nonlinear friction force of the isolators. Results indicate identical performance of all SIVC isolators in PGA scales up to 0.4 g. When subjected to PGA scales from 0.4 g to 1.0 g, polynomial friction pendulum isolator (PFPI) and variable curvature friction pendulum system (VCFPS) reduce base displacement greatly, while conical friction pendulum isolator (CFPI) and variable frequency pendulum isolator (VFPI) show amplified responses. However, in mitigating structural acceleration, performance of CFPI and VFPI, unlike PFPI and VCFPS, which perform poorly, is excellent. Thus, in a strong near‐fault earthquake, PFPI and VCFPS or CFPI and VFPI can be chosen based on whether reduction of base displacement or super‐structural acceleration is the main concern of designer, respectively. Copyright © 2015 John Wiley & Sons, Ltd.
Effectiveness of sliding isolators with variable curvature in near‐fault ground motions
Shaikhzadeh, Ali Akbar (author) / Karamoddin, Abbas (author)
The Structural Design of Tall and Special Buildings ; 25 ; 278-296
2016-04-25
19 pages
Article (Journal)
Electronic Resource
English
Theory and experimental study for sliding isolators with variable curvature
Online Contents | 2011
|Effect of supplemental damping on LRB and FPS seismic isolators under near-fault ground motions
British Library Online Contents | 2009
|Effect of supplemental damping on LRB and FPS seismic isolators under near-fault ground motions
Online Contents | 2009
|