A platform for research: civil engineering, architecture and urbanism
Simplified design procedure for frame buildings with viscoelastic or elastomeric structural dampers
A simplified design procedure (SDP) for preliminary seismic design of frame buildings with structural dampers is presented. The SDP uses elastic‐static analysis and is applicable to structural dampers made from viscoelastic (VE) or high‐damping elastomeric materials. The behaviour of typical VE materials and high‐damping elastomeric materials is often non‐linear, and the SDP idealizes these materials as linear VE materials. With this idealization, structures with VE or high‐damping elastomeric dampers can be designed and analysed using methods based on linear VE theory. As an example, a retrofit design for a typical non‐ductile reinforced concrete (RC) frame building using high‐damping elastomeric dampers is developed using the SDP. To validate the SDP, results from non‐linear dynamic time history analyses (NDTHA) are presented. Results from NDTHA demonstrate that the SDP estimates the seismic response with sufficient accuracy for design. It is shown that a non‐ductile RC frame building can be retrofit with high‐damping elastomeric dampers to remain essentially elastic under the design basis earthquake (DBE). Copyright © 2005 John Wiley & Sons, Ltd.
Simplified design procedure for frame buildings with viscoelastic or elastomeric structural dampers
A simplified design procedure (SDP) for preliminary seismic design of frame buildings with structural dampers is presented. The SDP uses elastic‐static analysis and is applicable to structural dampers made from viscoelastic (VE) or high‐damping elastomeric materials. The behaviour of typical VE materials and high‐damping elastomeric materials is often non‐linear, and the SDP idealizes these materials as linear VE materials. With this idealization, structures with VE or high‐damping elastomeric dampers can be designed and analysed using methods based on linear VE theory. As an example, a retrofit design for a typical non‐ductile reinforced concrete (RC) frame building using high‐damping elastomeric dampers is developed using the SDP. To validate the SDP, results from non‐linear dynamic time history analyses (NDTHA) are presented. Results from NDTHA demonstrate that the SDP estimates the seismic response with sufficient accuracy for design. It is shown that a non‐ductile RC frame building can be retrofit with high‐damping elastomeric dampers to remain essentially elastic under the design basis earthquake (DBE). Copyright © 2005 John Wiley & Sons, Ltd.
Simplified design procedure for frame buildings with viscoelastic or elastomeric structural dampers
Lee, Kyung‐Sik (author) / Fan, Chih‐Ping (author) / Sause, Richard (author) / Ricles, James (author)
Earthquake Engineering & Structural Dynamics ; 34 ; 1271-1284
2005-08-01
14 pages
Article (Journal)
Electronic Resource
English
Simplified design procedure for frame buildings with viscoelastic or elastomeric structural dampers
Online Contents | 2005
|Reduction of earthquake response of plane frame buildings by viscoelastic dampers
Online Contents | 2003
|Fatigue analyses of buildings with viscoelastic dampers
British Library Conference Proceedings | 2006
|