Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Ventilated Building Foundations in Greenland
The ventilated foundation systems used in certain permafrost areas in Greenland are described. Presented herein are those factors of heat transfer, moisture content, ground water conditions, and structural details which affected the designs as well as the siting, orientation, and maintenance problems involved.
Ventilated Building Foundations in Greenland
The ventilated foundation systems used in certain permafrost areas in Greenland are described. Presented herein are those factors of heat transfer, moisture content, ground water conditions, and structural details which affected the designs as well as the siting, orientation, and maintenance problems involved.
Ventilated Building Foundations in Greenland
Williams, Roger H. (Autor:in)
Transactions of the American Society of Civil Engineers ; 126 ; 657-664
01.01.2021
81961-01-01 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Ventilated Building Foundations in Greenland
ASCE | 2021
|Ventilated building foundations in Greenland
Engineering Index Backfile | 1959
|