Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Fatigue Behavior of Shear Connectors in High Performance Concrete
The paper deals with the fatigue behavior of headed studs and continuous shear connectors in high strength concrete. For both types of shear connectors cyclic push-out tests as well as large-scale beam tests under cyclic loading were carried out. The headed studs failed after a mean lifetime of 2.3-106 applying 40% to 50% of the static resistance as a maximum amplitude and R = 0.45 and 0.65, respectively. The residual strength after 1.0-106 load cycles was reduced by about 25% in comparison to the static push-out strength. The continuous shear connector, which is called "puzzle strip", did not fail in the fatigue tests with up to 2.0-106 load cycles, and there was no reduction in residual strength at all. The cyclic beam tests with headed studs show that the prediction of the fatigue failure according to the current standards is not satisfactory. A good prediction of the crack propagation (thus fatigue) can rather be accomplished by using an approach based on the crack-slip relationship. For the continuous puzzle strip the fatigue behavior depends on the state of the cutting-induced heat treatment of the surface material and on the surface roughness. For these connectors a threshold value for the crack propagation could be determined.
Fatigue Behavior of Shear Connectors in High Performance Concrete
The paper deals with the fatigue behavior of headed studs and continuous shear connectors in high strength concrete. For both types of shear connectors cyclic push-out tests as well as large-scale beam tests under cyclic loading were carried out. The headed studs failed after a mean lifetime of 2.3-106 applying 40% to 50% of the static resistance as a maximum amplitude and R = 0.45 and 0.65, respectively. The residual strength after 1.0-106 load cycles was reduced by about 25% in comparison to the static push-out strength. The continuous shear connector, which is called "puzzle strip", did not fail in the fatigue tests with up to 2.0-106 load cycles, and there was no reduction in residual strength at all. The cyclic beam tests with headed studs show that the prediction of the fatigue failure according to the current standards is not satisfactory. A good prediction of the crack propagation (thus fatigue) can rather be accomplished by using an approach based on the crack-slip relationship. For the continuous puzzle strip the fatigue behavior depends on the state of the cutting-induced heat treatment of the surface material and on the surface roughness. For these connectors a threshold value for the crack propagation could be determined.
Fatigue Behavior of Shear Connectors in High Performance Concrete
Feldmann, Markus (Autor:in) / Hechler, Oliver (Autor:in) / Hegger, Josef (Autor:in) / Rauscher, Sabine (Autor:in)
International Conference on Composite Construction in Steel and Concrete 2008 ; 2008 ; Devil's Thumb Ranch, Tabernash, Colorado, United States
25.02.2011
Aufsatz (Konferenz)
Elektronische Ressource
Englisch
Fatigue Behavior of Shear Connectors in High Performance Concrete
British Library Conference Proceedings | 2011
|Fatigue performance of bolted shear connectors
Taylor & Francis Verlag | 2022
|Shear behavior of large stud shear connectors embedded in ultra-high-performance concrete
SAGE Publications | 2020
|Load carrying behavior of shear connectors in ultra-high performance concrete
Tema Archiv | 2008
|Fatigue performance analysis of steel concrete composite structure PBH shear connectors
British Library Online Contents | 2016
|