Design and simulation of grid-photovoltaic hybrid system for an office complex ; Bir ofis kompleksi için fotovoltaik hibrit sistem şebeke tasarım ve simülasyonu
The research work presents the design and simulation of Grid – Photovoltaic (PV) hybrid system for an office complex. In this case, the School of Graduate Studies at the University of Port Harcourt, Rivers State is used as a case study. The purpose of the design is to augment the daily energy demand of School of Graduate Studies. The methodology involved obtaining the available solar irradiation energy data resources within the building of school of graduate studies vicinity with a peak irradiation of 5.242 kWh /m 2 /day. The load readings were taken from the distribution board of the school for a period of three weeks. The peak electrical load demand of the entire building was estimated to be 37 kVA. The peak load was split into Regular loads of 12 kVA and Basic load of 25 kVA. A total of 96 panels were connected in 8 parallel strings to give an area of about 141.7 m2 . The PV system design yields an average energy of 55.7kWh/day and the energy demand was estimated as 50.7kWh/day. This shows that the energy generated by the PV system can cater for the Regular loads in the office complex. ; Bu araştırma çalışması, bir ofis kompleksi için Fotovoltaik (PV) hibrit sistem şebeke tasarımı ve simülasyonunu sunar. Rivers Eyaleti, Port Harcourt Üniversitesi'ndeki Lisansüstü çalışmalar okulunda bir vaka çalışması olarak kullanılmıştır. Tasarımın amacı, Lisansüstü Eğitim Bilimleri Fakültesi'nin günlük enerji talebini karşılamaktır. Metodoloji, 5.242 kWh/m2 /gün'lük dik açı ışınlama ile lisansüstü çalışmalar okulunun binası içinde mevcut güneş ışınlama enerjisi veri kaynaklarının elde edilmesini içermektedir. Yük verileri üç hafta süreyle okul dağıtım hattından alınmıştır. Tüm binanın maksimum elektrik yükü talebi 37kVA olarak öngörülmüştür. Pik yük, 12 kVA'lık Normal yükler ve 25 kVA'lık Temel yük olarak bölünmüştür. Yaklaşık 141,7 m2 'lik bir alan sağlamak için 8 paralel dizide toplam 96 panel birleştirilmiştir. PV sistemi tasarımı ortalama 55.7kWh / gün enerji sağlayacak şekilde enerji talebi 50.7kWh/gün olarak öngörülmüştür. Bu, PV sistemi tarafından üretilen enerjinin ofis kompleksindeki Normal yükleri karşılayabileceğini göstermektedir.
Design and simulation of grid-photovoltaic hybrid system for an office complex ; Bir ofis kompleksi için fotovoltaik hibrit sistem şebeke tasarım ve simülasyonu
The research work presents the design and simulation of Grid – Photovoltaic (PV) hybrid system for an office complex. In this case, the School of Graduate Studies at the University of Port Harcourt, Rivers State is used as a case study. The purpose of the design is to augment the daily energy demand of School of Graduate Studies. The methodology involved obtaining the available solar irradiation energy data resources within the building of school of graduate studies vicinity with a peak irradiation of 5.242 kWh /m 2 /day. The load readings were taken from the distribution board of the school for a period of three weeks. The peak electrical load demand of the entire building was estimated to be 37 kVA. The peak load was split into Regular loads of 12 kVA and Basic load of 25 kVA. A total of 96 panels were connected in 8 parallel strings to give an area of about 141.7 m2 . The PV system design yields an average energy of 55.7kWh/day and the energy demand was estimated as 50.7kWh/day. This shows that the energy generated by the PV system can cater for the Regular loads in the office complex. ; Bu araştırma çalışması, bir ofis kompleksi için Fotovoltaik (PV) hibrit sistem şebeke tasarımı ve simülasyonunu sunar. Rivers Eyaleti, Port Harcourt Üniversitesi'ndeki Lisansüstü çalışmalar okulunda bir vaka çalışması olarak kullanılmıştır. Tasarımın amacı, Lisansüstü Eğitim Bilimleri Fakültesi'nin günlük enerji talebini karşılamaktır. Metodoloji, 5.242 kWh/m2 /gün'lük dik açı ışınlama ile lisansüstü çalışmalar okulunun binası içinde mevcut güneş ışınlama enerjisi veri kaynaklarının elde edilmesini içermektedir. Yük verileri üç hafta süreyle okul dağıtım hattından alınmıştır. Tüm binanın maksimum elektrik yükü talebi 37kVA olarak öngörülmüştür. Pik yük, 12 kVA'lık Normal yükler ve 25 kVA'lık Temel yük olarak bölünmüştür. Yaklaşık 141,7 m2 'lik bir alan sağlamak için 8 paralel dizide toplam 96 panel birleştirilmiştir. PV sistemi tasarımı ortalama 55.7kWh / gün enerji sağlayacak şekilde enerji talebi 50.7kWh/gün olarak öngörülmüştür. Bu, PV sistemi tarafından üretilen enerjinin ofis kompleksindeki Normal yükleri karşılayabileceğini göstermektedir.
Design and simulation of grid-photovoltaic hybrid system for an office complex ; Bir ofis kompleksi için fotovoltaik hibrit sistem şebeke tasarım ve simülasyonu
Big Alabo, Ameze (Autor:in) / Duruji, Tomenna (Autor:in)
01.01.2021
1
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
Dijital Göçebeler için Mobil Yaşam ve Mekânsal Tasarım Çözümlerinin İncelenmesi
BASE | 2025
|