Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
ANALISA EKSERGI MESIN PENDINGIN KOMPRESI UAP
Exergy is part of the energy that can be converted into work. Analysis of allergy is a method of analysis which isthe application of the second thermodinamika term used to determine the efficiency or absence of a process inthe use of energy. The purpose of the analysis of the allergy is to find a location in a process that is inefficientenergy. Air Conditioner is a maintenance process for air, temperature, humidity, cleanliness and distributionsimultaneously to achieve the comfortable conditions that residents need .This study is intended to obtain anexergy by varying the rotation of the condenser fan. A device capable of providing detailed measurement data.AC used type split 1 PK capacity, which is converted to portable form. In the data collection is done variation ofcondenser fan speed rotation, with 1 / 4.1 / 2.3 / 4 dimer openings and 1 dimer openings After the test, thecalculation and discussion can be concluded, good performance at 30 minutes, current openings dimer 1 withvalue 2.47583. While the value of exergy at the highest exergency value at the opening current dimer ½, 45minutes with a value of 3.076 kJ / kg ,Keywords: Exergy, COP, PF, AC, dimer, split, portable.
ANALISA EKSERGI MESIN PENDINGIN KOMPRESI UAP
Exergy is part of the energy that can be converted into work. Analysis of allergy is a method of analysis which isthe application of the second thermodinamika term used to determine the efficiency or absence of a process inthe use of energy. The purpose of the analysis of the allergy is to find a location in a process that is inefficientenergy. Air Conditioner is a maintenance process for air, temperature, humidity, cleanliness and distributionsimultaneously to achieve the comfortable conditions that residents need .This study is intended to obtain anexergy by varying the rotation of the condenser fan. A device capable of providing detailed measurement data.AC used type split 1 PK capacity, which is converted to portable form. In the data collection is done variation ofcondenser fan speed rotation, with 1 / 4.1 / 2.3 / 4 dimer openings and 1 dimer openings After the test, thecalculation and discussion can be concluded, good performance at 30 minutes, current openings dimer 1 withvalue 2.47583. While the value of exergy at the highest exergency value at the opening current dimer ½, 45minutes with a value of 3.076 kJ / kg ,Keywords: Exergy, COP, PF, AC, dimer, split, portable.
ANALISA EKSERGI MESIN PENDINGIN KOMPRESI UAP
andina, mega (Autor:in) / suryadimal, Suryadimal (Autor:in) / mahyoeddin, yovial (Autor:in)
08.02.2018
ABSTRACT OF UNDERGRADUATE RESEARCH, FACULTY OF INDUSTRIAL TECHNOLOGY, BUNG HATTA UNIVERSITY; Vol. 11 No. 2 (2018): Abstrak dan jurnal teknik mesin Univ Bung Hatta ; JURNAL FAKULTAS TEKNIK INDUSTRI; Vol 11 No 2 (2018): Abstrak dan jurnal teknik mesin Univ Bung Hatta
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
DDC:
690
PENGARUH MEDIA PENDINGIN AIR PADA KONDENSOR TERHADAP KEMAMPUAN KERJA MESIN PENDINGIN
DOAJ | 2014
|ANALISA KEBUTUHAN BEBAN PENDINGIN DAN DAYA ALAT PENDINGIN AC UNTUK AULA KAMPUS 2 UM METRO.
DOAJ | 2013
|Perancangan Sistem Pendingin pada Prototipe Mesin Injeksi Molding Double Barrel
DOAJ | 2025
|PENGARUH JENIS REFRIGERANT DAN BEBAN PENDINGINAN TERHADAP KEMAMPUAN KERJA MESIN PENDINGIN
DOAJ | 2014
|