A practical methodology to assess corrosion in concrete sewer pipes
The combination of Neutron Tomography (NT), Scanning Electron Microscopy (SEM, with and without elemental analysis), pH profiling and Microindentation Mapping techniques was used to develop a methodology for the assessment of concrete sewer pipe deterioration. We demonstrate a viable method for health monitoring of concrete sewer pipes and the evaluation of competing mitigation strategies.
A practical methodology to assess corrosion in concrete sewer pipes
The combination of Neutron Tomography (NT), Scanning Electron Microscopy (SEM, with and without elemental analysis), pH profiling and Microindentation Mapping techniques was used to develop a methodology for the assessment of concrete sewer pipe deterioration. We demonstrate a viable method for health monitoring of concrete sewer pipes and the evaluation of competing mitigation strategies.
A practical methodology to assess corrosion in concrete sewer pipes
Taheri, Shima (Autor:in) / Ams, Martin (Autor:in) / Bustamante, Heriberto (Autor:in) / Vorreiter, Louisa (Autor:in) / Withford, Michael (Autor:in) / Clark, Simon Martin (Autor:in)
01.01.2018
Taheri , S , Ams , M , Bustamante , H , Vorreiter , L , Withford , M & Clark , S M 2018 , ' A practical methodology to assess corrosion in concrete sewer pipes ' , MATEC Web of Conferences , vol. 199 , 06010 . https://doi.org/10.1051/matecconf/201819906010