Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
A practical methodology to assess corrosion in concrete sewer pipes
The combination of Neutron Tomography (NT), Scanning Electron Microscopy (SEM, with and without elemental analysis), pH profiling and Microindentation Mapping techniques was used to develop a methodology for the assessment of concrete sewer pipe deterioration. We demonstrate a viable method for health monitoring of concrete sewer pipes and the evaluation of competing mitigation strategies.
A practical methodology to assess corrosion in concrete sewer pipes
The combination of Neutron Tomography (NT), Scanning Electron Microscopy (SEM, with and without elemental analysis), pH profiling and Microindentation Mapping techniques was used to develop a methodology for the assessment of concrete sewer pipe deterioration. We demonstrate a viable method for health monitoring of concrete sewer pipes and the evaluation of competing mitigation strategies.
A practical methodology to assess corrosion in concrete sewer pipes
Taheri Shima (Autor:in) / Ams Martin (Autor:in) / Bustamante Heriberto (Autor:in) / Vorreiter Louisa (Autor:in) / Withford Michael (Autor:in) / Martin Clark Simon (Autor:in)
2018
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
British Library Online Contents | 2005
Durability control of concrete sewer pipes
British Library Conference Proceedings | 1999
|Quality Assurance of Concrete Sewer Pipes
British Library Conference Proceedings | 1994
|