Seismic evaluation and retrofitting of an existing building in Athens using pushover analysis
Earthquakes are one of the biggest problems in civil engineering all over the world. Due to earthquakes, great disasters in cities with collapsed structures and human losses have been caused. More specific, old buildings that have been built based on old regulations and design building codes do not fulfil anymore the new criteria of seismic designing.In this study, an old building has been evaluated for the seismic load in order to decide if there is a need for strengthening it using retrofitting methods. The seismic evaluation is based on Eurocode 8 and after the application of retrofitting techniques the building fulfilled its seismic design criteria. The existing building is a four-storey, concrete structure that has been built in 1970 and is located in Athens (the capital city of Greece). The seismic evaluation is conducted by using the software Seismostruct.Two analyses are performed in order to evaluate the seismic behavior of the building. First, an eigenvalue analysis is conducted before and after retrofitting. By using this analysis the torsional sensitivity of the building has been checked. Then, using pushover analysis, the comparison of the target displacement (expected displacement of the building for the design seismic action) for each limit state and the displacement of the building when the first member of the building reached the corresponding limit state, is presented. Target displacement must not be greater than this displacement in order to ensure the safety of the building. If the comparison shows that target displacement is greater, the weak links in the facility should be identified and the proper retrofitting method should be applied for the improvement of the seismic behavior of the building. Pushover analysis is conducted before and after the application of retrofitting methods.After performing the eigenvalue and pushover analysis of the existing building it was found that the building was torsional sensitive and shear failures occurred in many beams of the structure. Regarding the ...
Seismic evaluation and retrofitting of an existing building in Athens using pushover analysis
Earthquakes are one of the biggest problems in civil engineering all over the world. Due to earthquakes, great disasters in cities with collapsed structures and human losses have been caused. More specific, old buildings that have been built based on old regulations and design building codes do not fulfil anymore the new criteria of seismic designing.In this study, an old building has been evaluated for the seismic load in order to decide if there is a need for strengthening it using retrofitting methods. The seismic evaluation is based on Eurocode 8 and after the application of retrofitting techniques the building fulfilled its seismic design criteria. The existing building is a four-storey, concrete structure that has been built in 1970 and is located in Athens (the capital city of Greece). The seismic evaluation is conducted by using the software Seismostruct.Two analyses are performed in order to evaluate the seismic behavior of the building. First, an eigenvalue analysis is conducted before and after retrofitting. By using this analysis the torsional sensitivity of the building has been checked. Then, using pushover analysis, the comparison of the target displacement (expected displacement of the building for the design seismic action) for each limit state and the displacement of the building when the first member of the building reached the corresponding limit state, is presented. Target displacement must not be greater than this displacement in order to ensure the safety of the building. If the comparison shows that target displacement is greater, the weak links in the facility should be identified and the proper retrofitting method should be applied for the improvement of the seismic behavior of the building. Pushover analysis is conducted before and after the application of retrofitting methods.After performing the eigenvalue and pushover analysis of the existing building it was found that the building was torsional sensitive and shear failures occurred in many beams of the structure. Regarding the ...
Seismic evaluation and retrofitting of an existing building in Athens using pushover analysis
Lazaris, Angelos (Autor:in)
01.01.2019
19248
Hochschulschrift
Elektronische Ressource
Englisch
Seismic Assessment of Building Using Pushover Analysis
British Library Conference Proceedings | 2000
|Pushover Analysis of a Seismic Strengthening of an Existing Building Reinforced Concrete Structure
Trans Tech Publications | 2013
|EXISTING BUILDING EXTENSION METHOD AND SEISMIC RETROFITTING METHOD
Europäisches Patentamt | 2016
|Evaluation of Seismic Capacity of RCC Building Through Pushover Analysis
Springer Verlag | 2024
|A Pushover Seismic Analysis and Retrofitting Method Applied to Low-Rise RC School Buildings
SAGE Publications | 2015
|