Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Post-installed reinforcing bars – Requirements for their reliable use
Post-installed steel reinforcing bar connections carried out with anchoring mortars sufficiently qualified to fulfill the requirements for safety, serviceability, and durability of concrete structures are capable of developing bond behavior equivalent to cast-in-place steel reinforcing bars. Therefore, their design can be performed according to reinforced concrete design provisions. Post-installed anchorage technology offers fast and convenient solution to introduce new reinforcement in an existing reinforced concrete (RC) structural system, and hence serves as effective method for strengthening and upgrade of existing structures. The behavior of post-installed reinforcement depends on the existing condition of the concrete member. This paper addresses the aspects related to base material, installation, environment, and load conditions in service. This paper also comments on the qualification of anchoring mortars and provides information on the design of post-installed reinforcing bars as reinforcement (RC design perspective) or as anchorage (adhesive anchor design perspective) in the light of corresponding provisions necessary to achieve the same safety level in service compared to connections with cast-in steel reinforcing bars.
Post-installed reinforcing bars – Requirements for their reliable use
Post-installed steel reinforcing bar connections carried out with anchoring mortars sufficiently qualified to fulfill the requirements for safety, serviceability, and durability of concrete structures are capable of developing bond behavior equivalent to cast-in-place steel reinforcing bars. Therefore, their design can be performed according to reinforced concrete design provisions. Post-installed anchorage technology offers fast and convenient solution to introduce new reinforcement in an existing reinforced concrete (RC) structural system, and hence serves as effective method for strengthening and upgrade of existing structures. The behavior of post-installed reinforcement depends on the existing condition of the concrete member. This paper addresses the aspects related to base material, installation, environment, and load conditions in service. This paper also comments on the qualification of anchoring mortars and provides information on the design of post-installed reinforcing bars as reinforcement (RC design perspective) or as anchorage (adhesive anchor design perspective) in the light of corresponding provisions necessary to achieve the same safety level in service compared to connections with cast-in steel reinforcing bars.
Post-installed reinforcing bars – Requirements for their reliable use
Werner Fuchs (Autor:in) / Jan Hofmann (Autor:in)
2021
Aufsatz (Zeitschrift)
Elektronische Ressource
Unbekannt
Metadata by DOAJ is licensed under CC BY-SA 1.0
Seismic Design of Anchorages Using Post-installed Reinforcing Bars
Springer Verlag | 2023
|Design of Anchorages in Connections Using Post-installed Reinforcing Bars
Springer Verlag | 2023
|Pullout Strength of Post-Installed Adhesive Anchors Using Glass FRP Reinforcing Bars
British Library Conference Proceedings | 2007
|Bond stresses in post‐installed reinforcing bars derived via fiber optic sensors
Wiley | 2024
|