Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Plain concrete cylinders 5 in. in diam were tested at 28 days under loading rate which produced stress of 75 lb/in.2 per min; average ultimate tensile strength from tests on 36 specimens was 454 lb/in.2; majority of specimens broke within middle third of length; comparison between compressive and direct tensile strengths.
Plain concrete cylinders 5 in. in diam were tested at 28 days under loading rate which produced stress of 75 lb/in.2 per min; average ultimate tensile strength from tests on 36 specimens was 454 lb/in.2; majority of specimens broke within middle third of length; comparison between compressive and direct tensile strengths.
Direct tensile strength of concrete
Civ Eng (Lond)
Humphreys, R. (Autor:in)
Civil Engineering ; 52
1957
3 pages