Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Tests on beams with sustained loading
Six pairs of concrete beams, each containing one beam reinforced with mild steel and one with Tentor steel with span/depth ratios of 20, 30 and 40, and all designed for same bending moment, were kept under full design load for 4 3/4 yr; during this period deflections increased to 3.14-3.94 times original; all beams became unserviceable, although their factor of safety against failure was over 3; test results were compared with deflections calculated by various methods; tests proved that limiting slenderness ratios in CP 114(1957), Clause 309a, Table 13, are excessive if substantial proportion of design superimposed load is to be supported for long period; revision is suggested.
Tests on beams with sustained loading
Six pairs of concrete beams, each containing one beam reinforced with mild steel and one with Tentor steel with span/depth ratios of 20, 30 and 40, and all designed for same bending moment, were kept under full design load for 4 3/4 yr; during this period deflections increased to 3.14-3.94 times original; all beams became unserviceable, although their factor of safety against failure was over 3; test results were compared with deflections calculated by various methods; tests proved that limiting slenderness ratios in CP 114(1957), Clause 309a, Table 13, are excessive if substantial proportion of design superimposed load is to be supported for long period; revision is suggested.
Tests on beams with sustained loading
Mag Concrete Research
Hajnal-Konyi, K. (Autor:in)
1963
12 pages
Aufsatz (Zeitschrift)
Englisch
© Metadata Copyright Elsevier B. V. All rights reserved.
Deflection of Cracked RC Beams under Sustained Loading
British Library Online Contents | 2000
|Shear Capacity of Concrete Beams under Sustained Loading
British Library Conference Proceedings | 2013
|Tests of reinforced concrete columns under sustained loading
Engineering Index Backfile | 1938
|Preliminary report on static and sustained loading tests
Engineering Index Backfile | 1968
|Tests of reinforced concrete columns under sustained loading
Engineering Index Backfile | 1938
|