Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Physical and numerical modelling of strip footing on geogrid reinforced transparent sand
Abstract This paper presents the results of laboratory scale plate load tests on transparent soils reinforced with biaxial polypropylene geogrids. The influence of reinforcement length and number of reinforcement layers on the load-settlement response of the reinforced soil foundation was assessed by varying the reinforcement length and the number of geogrid layers, each spaced at 25% of footing width. The deformations of the reinforcement layers and soil under strip loading were examined with the aid of laser transmitters (to illuminate the geogrid reinforcement) and digital camera. A two-dimensional finite difference program was used to study the fracture of geogrid under strip loading considering the geometry of the model tests. The bearing capacity and stiffness of the reinforced soil foundation has increased with the increase in the reinforcement length and number of reinforcement layers, but the increase is more prominent by increasing number of reinforcement layers. The results from the physical and numerical modelling on reinforced soil foundation reveal that fracture of geogrid could initiate in the bottom layer of reinforcement and progress to subsequent upper layers. The displacement and stress contours along with the mobilized tensile force distribution obtained from the numerical simulations have complimented the observations made from the experiments.
Physical and numerical modelling of strip footing on geogrid reinforced transparent sand
Abstract This paper presents the results of laboratory scale plate load tests on transparent soils reinforced with biaxial polypropylene geogrids. The influence of reinforcement length and number of reinforcement layers on the load-settlement response of the reinforced soil foundation was assessed by varying the reinforcement length and the number of geogrid layers, each spaced at 25% of footing width. The deformations of the reinforcement layers and soil under strip loading were examined with the aid of laser transmitters (to illuminate the geogrid reinforcement) and digital camera. A two-dimensional finite difference program was used to study the fracture of geogrid under strip loading considering the geometry of the model tests. The bearing capacity and stiffness of the reinforced soil foundation has increased with the increase in the reinforcement length and number of reinforcement layers, but the increase is more prominent by increasing number of reinforcement layers. The results from the physical and numerical modelling on reinforced soil foundation reveal that fracture of geogrid could initiate in the bottom layer of reinforcement and progress to subsequent upper layers. The displacement and stress contours along with the mobilized tensile force distribution obtained from the numerical simulations have complimented the observations made from the experiments.
Physical and numerical modelling of strip footing on geogrid reinforced transparent sand
Chen, Jianfeng (Autor:in) / Guo, Xiaopeng (Autor:in) / Sun, Rui (Autor:in) / Rajesh, Sathiyamoorthy (Autor:in) / Jiang, Song (Autor:in) / Xue, Jianfeng (Autor:in)
Geotextiles and Geomembranes ; 49 ; 399-412
01.01.2020
14 pages
Aufsatz (Zeitschrift)
Elektronische Ressource
Englisch
The Performance of Strip Footing Resting on Geogrid-Reinforced Dune Sand
British Library Conference Proceedings | 2016
|Behavior of strip footing on geogrid-reinforced sand over a soft clay slope
Tema Archiv | 2007
|