Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Energy-Conserving Site-Design Case Study, Radisson, New York. Final Report
Radisson is a 2,950-acre new community currently being developed by the New York State Urban Development Corporation and located in central New York, 12 miles north-west of Syracuse. Case-study sites selected for this project are a 95-acre residential site and the 51-acre Town Center of the new community. Development on the Residential Site is a low-density (2.8 dwelling units/acre) mixture of single-family, townhouse and multi-family units. Development on the Town Center site is a mixture of small-scale commercial use (144,000 sq. ft.) and 330+ multi-family dwelling units. Energy-conserving plans developed for both sites have focused on passive measures to reduce energy use for space heating. Utility-system options have been identified for both sites, but require further study as to feasibility and cost. This report summarizes energy savings and cost differentials due to passive measures incorporated in both the residential and Town Center Plans. The future implementation schedule, also discussed, summarizes the procedures an schedule required for implementation of the passive measures, as well as further study required for the development of utility-system options. 4 tables. (ERA citation 05:029265)
Energy-Conserving Site-Design Case Study, Radisson, New York. Final Report
Radisson is a 2,950-acre new community currently being developed by the New York State Urban Development Corporation and located in central New York, 12 miles north-west of Syracuse. Case-study sites selected for this project are a 95-acre residential site and the 51-acre Town Center of the new community. Development on the Residential Site is a low-density (2.8 dwelling units/acre) mixture of single-family, townhouse and multi-family units. Development on the Town Center site is a mixture of small-scale commercial use (144,000 sq. ft.) and 330+ multi-family dwelling units. Energy-conserving plans developed for both sites have focused on passive measures to reduce energy use for space heating. Utility-system options have been identified for both sites, but require further study as to feasibility and cost. This report summarizes energy savings and cost differentials due to passive measures incorporated in both the residential and Town Center Plans. The future implementation schedule, also discussed, summarizes the procedures an schedule required for implementation of the passive measures, as well as further study required for the development of utility-system options. 4 tables. (ERA citation 05:029265)
Energy-Conserving Site-Design Case Study, Radisson, New York. Final Report
1979
155 pages
Report
Keine Angabe
Englisch
Radisson specific pavement studies - 9A test site
British Library Conference Proceedings | 1999
|British Library Online Contents | 2004
|Slovakia: Radisson SAS Carlton
British Library Online Contents | 2003
|