Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Energy Conserving Site Design Case Study: Shenandoah, Georgia. Final Report
The case study examines the means by which energy conservation can be achieved at an aggregate community level by using proper planning and analytical techniques for a new town, Shenandoah, Georgia, located twenty-five miles southwest of Atlanta's Hartsfield International Airport. A potentially implementable energy conservation community plan is achieved by a study team examining the land use options, siting characteristics of each building type, alternate infrastructure plans, possible decentralized energy options, and central utility schemes to determine how community energy conservation can be achieved by use of pre-construction planning. The concept for the development of mixed land uses as a passively sited, energy conserving community is based on a plan (Level 1 Plan) that uses the natural site characteristics, maximizes on passive energy siting requirement, and allows flexibility for the changing needs of the developers. The Level 2 Plan is identical with Level 1 plan plus a series of decentraized systems that have been added to the residential units: the single-family detached, the apartments, and the townhouses. Level 3 Plan is similar to the Level 1 Plan except that higher density dwellings have been moved to areas adjacent to central site. The total energy savings for each plan relative to the conventional plan are indicated. (ERA citation 05:038307)
Energy Conserving Site Design Case Study: Shenandoah, Georgia. Final Report
The case study examines the means by which energy conservation can be achieved at an aggregate community level by using proper planning and analytical techniques for a new town, Shenandoah, Georgia, located twenty-five miles southwest of Atlanta's Hartsfield International Airport. A potentially implementable energy conservation community plan is achieved by a study team examining the land use options, siting characteristics of each building type, alternate infrastructure plans, possible decentralized energy options, and central utility schemes to determine how community energy conservation can be achieved by use of pre-construction planning. The concept for the development of mixed land uses as a passively sited, energy conserving community is based on a plan (Level 1 Plan) that uses the natural site characteristics, maximizes on passive energy siting requirement, and allows flexibility for the changing needs of the developers. The Level 2 Plan is identical with Level 1 plan plus a series of decentraized systems that have been added to the residential units: the single-family detached, the apartments, and the townhouses. Level 3 Plan is similar to the Level 1 Plan except that higher density dwellings have been moved to areas adjacent to central site. The total energy savings for each plan relative to the conventional plan are indicated. (ERA citation 05:038307)
Energy Conserving Site Design Case Study: Shenandoah, Georgia. Final Report
1980
389 pages
Report
Keine Angabe
Englisch
Policies, Regulations & Studies , Planned communities , Buildings , Design , Economic analysis , Energy conservation , Georgia , Greenhouses , Human populations , Implementation , Land use , Life-cycle cost , Passive solar cooling systems , Passive solar heating systems , Public utilities , Site selection , Solar radiation , Solar water heaters , Systems analysis , Trombe walls , ERDA/320600 , ERDA/140900 , ERDA/291000
NTIS | 1994