National Dam Inspection Program. Beaver Dam (NDI I.D. Number PA-00453, Pennder I.D. Number 65-7), Ohio River Basin, Beaver Run, Westmoreland County, Pennsylvania. Phase I Inspection Report
Beaver Dam is an earth embankment approximately 32 feet high and 385 feet long (including spillway). The dam is constructed with a masonry spillway located about 35 feet left of the right abutment. The crest of the spillway is 100 feet long and about 11 feet below the top of its wingwalls. Based on a visual inspection, operational history, and available engineering data, the dam is consisered to be in poor condition. The defunct facility has been essentially abandoned since 1952 and its reservoir is sediment filled. Results of the hydrologic and hydraulic analysis indicate that the facility is capable of passing and/or storing only 36 percent of the PMF without embankment overtopping. Structural deficiencies noted by the inspection team included substantial embankment overgrowth, an access road cut through the embankment near the left abutment, cracking of the masonry spillway wingwalls, and a sediment filled reservoir. Due to the seriously inadequate spillway and overall poor condition, the facility is considered unsafe but non-emergency as failure is not considered imminent.
National Dam Inspection Program. Beaver Dam (NDI I.D. Number PA-00453, Pennder I.D. Number 65-7), Ohio River Basin, Beaver Run, Westmoreland County, Pennsylvania. Phase I Inspection Report
Beaver Dam is an earth embankment approximately 32 feet high and 385 feet long (including spillway). The dam is constructed with a masonry spillway located about 35 feet left of the right abutment. The crest of the spillway is 100 feet long and about 11 feet below the top of its wingwalls. Based on a visual inspection, operational history, and available engineering data, the dam is consisered to be in poor condition. The defunct facility has been essentially abandoned since 1952 and its reservoir is sediment filled. Results of the hydrologic and hydraulic analysis indicate that the facility is capable of passing and/or storing only 36 percent of the PMF without embankment overtopping. Structural deficiencies noted by the inspection team included substantial embankment overgrowth, an access road cut through the embankment near the left abutment, cracking of the masonry spillway wingwalls, and a sediment filled reservoir. Due to the seriously inadequate spillway and overall poor condition, the facility is considered unsafe but non-emergency as failure is not considered imminent.
National Dam Inspection Program. Beaver Dam (NDI I.D. Number PA-00453, Pennder I.D. Number 65-7), Ohio River Basin, Beaver Run, Westmoreland County, Pennsylvania. Phase I Inspection Report
1979
140 pages
Report