Eine Plattform für die Wissenschaft: Bauingenieurwesen, Architektur und Urbanistik
Accuracy analysis of automatic distortion correction
Abstract The paper addresses the problem of the automatic distortion removal from images acquired with non-metric SLR camera equipped with prime lenses. From the photogrammetric point of view the following question arises: is the accuracy of distortion control data provided by the manufacturer for a certain lens model (not item) sufficient in order to achieve demanded accuracy? In order to obtain the reliable answer to the aforementioned problem the two kinds of tests were carried out for three lens models. Firstly the multi-variant camera calibration was conducted using the software providing full accuracy analysis. Secondly the accuracy analysis using check points took place. The check points were measured in the images resampled based on estimated distortion model or in distortion-free images simply acquired in the automatic distortion removal mode. The extensive conclusions regarding application of each calibration approach in practice are given. Finally the rules of applying automatic distortion removal in photogrammetric measurements are suggested.
Accuracy analysis of automatic distortion correction
Abstract The paper addresses the problem of the automatic distortion removal from images acquired with non-metric SLR camera equipped with prime lenses. From the photogrammetric point of view the following question arises: is the accuracy of distortion control data provided by the manufacturer for a certain lens model (not item) sufficient in order to achieve demanded accuracy? In order to obtain the reliable answer to the aforementioned problem the two kinds of tests were carried out for three lens models. Firstly the multi-variant camera calibration was conducted using the software providing full accuracy analysis. Secondly the accuracy analysis using check points took place. The check points were measured in the images resampled based on estimated distortion model or in distortion-free images simply acquired in the automatic distortion removal mode. The extensive conclusions regarding application of each calibration approach in practice are given. Finally the rules of applying automatic distortion removal in photogrammetric measurements are suggested.
Accuracy analysis of automatic distortion correction
Kolecki, Jakub (Autor:in) / Rzonca, Antoni (Autor:in)
2015
Aufsatz (Zeitschrift)
Englisch
Symmetric Distortion Correction in Asphere Manufacturing
British Library Online Contents | 2013
|Image distortion correction on structure identification of weft knitted fabric
British Library Online Contents | 2016
|Study on highly-precise method for instrument response distortion correction
British Library Online Contents | 2009
|Model-Based Correction of Image Distortion in Scanning Electron Microscopy
British Library Online Contents | 2010
|Motion picture theatre sound with screen interference correction and low distortion
British Library Conference Proceedings | 1994
|